Airvent UV-C FiltAir 45 Manual de instrucciones - Página 9

Navegue en línea o descargue pdf Manual de instrucciones para Equipos de laboratorio Airvent UV-C FiltAir 45. Airvent UV-C FiltAir 45 16 páginas.

Airvent UV-C FiltAir 45 Manual de instrucciones
B)
Marked Through the Unit
Place the unit at its designated place, and press it firmly against
the wall. Either use the optional feet, or leave at least 120 mm free
space below the unit.
Attention!
After mounting the feet, the unit must be raised to a
vertical position by lifting it from two sides. Do not lift by tilting
it on its feet!
Mark the location of the boreholes on the wall through the
holes on the back sheet of the unit (marked in red), and then
put the unit aside for the duration of drilling. The machine must
be secured against tipping over during the drilling.
Size
UV-C FiltAir 15
UV-C FiltAir 30
UV-C FiltAir 45
UV-C FiltAir 75

Mounting the unit to the wall

The unit, standing on its feet, needs to be placed back to its des-
ignated place and then it must be firmly fixed to the wall in four
places with screws.

Inserting UV-C Fluorescent Tubes

The fluorescent lamps to be inserted into the socket at the bottom
and top and rotated 90 degrees to the right or left until they click. Pay
attention to holding them at the bottom and top with both hands.
Attention!
It is recommended to use clean gloves or textile to
insert the fluorescent lamps, or to wipe the tubes with a slightly
damp alcohol swab after insertion. It is not permitted for the user
to open the reactor space and insert the UV-C lamps!
Inserting fluorescent lamps
C (mm)
400
600
600
1050
Mark the location of the boreholes through the holes on the back sheet of the unit

Inserting the Air Filter

The filter must be gently pressed into the bottom of the filter
housing until it stops and then tilted into its place. Then fix the
filter by turning the clips.
Inserting the air filter
C
Ø10
Ø10
Ø10
Ø10
110
C
www.airvent.eu
9