I
NSTALLATION
11
Adjust relief cartridges
For over-pressure protection, the relief valve
cartridges for both the CLAMP and SIDE-
SHIFT functions should be adjusted to
match the truck hydraulic flow rate.
Clamp relief adjustment:
A
Confirm that the truck pressure is
between 2300–2600 psi (160–180 bar)
at the carriage hose terminal.
B
Install a 3000-psi (200 bar) pressure
gauge on the test port of the main valve.
(No. 4 O-ring fitting required).
C
Cycle arms to full open. Slowly close
arms while clamping a maximum rigid
load (or clamp force indicator). Hold the
lever in the CLAMP position and acceler-
ate the engine to develop full pressure.
D
Adjust the CLAMP relief cartridge for an
indicated 2300 psi (160 bar). Turn
clockwise to increase pressure, counter-
clockwise to decrease. Tighten jam nut
and replace cap.
CL0623.ill
Decrease
Pressure (CCW)
5/16-in. (8 mm)
Allen Wrench
NON-SIDESHIFTING VALVE
Relief Valve
Cartridge
Increase
Pressure
(CW)
3/4-in. (19 mm)
3/4-in. (19 mm)
Jam Nut
Jam Nut
Adjustment
Screw
Cap
F
Sideshift Relief Cartridge
SIDESHIFTING VALVE
WARNING: Before removing hydraulic lines
or components, relieve pressure in the
hydraulic system. Turn the truck off and
open the truck auxiliary control valves
several times in both directions.
Sideshift relief adjustment:
E
With a maximum load clamped, sideshift full left
and full right while checking for an arm speed of
8–10 in./sec.
F
Using an Allen wrench, adjust the SIDESHIFT
relief cartridge counterclockwise (CCW) 1/4-turn.
Repeat Steps E and F until sideshift speed slows
(relief opening).
G
Readjust cartridge clockwise (CW) 1/4-turn.
Tighten jam nut and replace cap.
B
C
D
Clamp Relief Cartridge
CL0622.ill
E
CL0435.ill
FRONT
SIDESHIFTING VALVE
WITH REGENERATION
C
7