3.1

INSPECTION OF PURCHASED PRODUCT

Inspect the equipment before its use to check for damages caused by transportation or
improper storage. Make sure that all standard and optional components have been delivered.
3.2

INSTALLATION CONDITIONS

The gun must be fed with a maximum pressure of 500 bar (7100psi).
To mount the equipment proceed as follows (use the drawing below):
Fasten the paint inlet hose to the gun connection (A).
+
Choose which nozzles and gun filter better adapt to
+
the operation which must be performed.
WARNING
Always use high pressure hoses to carry out all the
connections. Before you start using the equipment, make
sure the connections and hoses are in perfect working
conditions, that is without holes, bends or splits.
WARNING
Always operate with the minimum pressure needed to
obtain the results desired. Increasing pressure does not
improve the painting quality, on the contrary it can wear
the nozzle.
WARNING
If the spraying rate is not optimal, do not increase the
paint pressure, but replace the tip with a larger-size one.
3.3

EQUIPMENT AND CONDITIONS NEEDED TO WORK

Painting operations
MUST
be carried out in an appropriate booth equipped with a filtering
system. Do not use the unit if the filtering system is not activated. Always wear protection
gloves, goggles, breathing filters with active carbon and adequate clothing for the protection
of the entire body. Ground all the unit components (using the given cable) because static
currents could create sparks and explosions. All the equipment standard hoses are made of
antistatic material.
®