Disassembling and assembling iSave 21
13.
Make sure that the guide pin is located in
the location hole.
15.
Bolt the flange onto the vane pump.
Tighten the bolt with 30 Nm ±3 Nm.
17.
Change the two O-rings in the flange.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
14.
Change the O-ring in the HP out
connection flange.
16.
Fit the coupling into the pump.
Glue the threat on the bolt with "Loctite
270" and tighten the bolt with 10 Nm±1 Nm.