Restoring Defaults using CLI

The device can be restored to factory defaults using the CLI, as described in the procedure
below.
2.1

Establishing CLI Communication

Before you can restore defaults, you need to establish CLI communication with the device.
To restore factory defaults using CLI:
1.
Cable the device's RS-232 serial port to the COM1 or COM2 communication port on
your PC. For a detailed description on serial cabling, refer to the device's Installation
Manual.
2.
Establish a serial communication with the device, using a serial communication
program such as HyperTerminal. The table below lists the COM port settings.
Parameter
Baud Rate
Data bits
Parity
Stop bits
Flow control
Version 6.4
Table 2-1: COM Port Settings
Devices
Mediant 600
Mediant 800 MSBG
Mediant 800 Gateway & E-SBC
Mediant 1000 MSBG
Mediant 1000
Mediant 1000B Gateway & E-SBC
Mediant 2000
Mediant 3000
Mediant 4000 E-SBC
MP-11x
MP-124
All
All
All
All
9
2. Restoring Defaults using CLI
Value
115,200 bps
9,600 bps
115,200 bps
8
None
1
None
May 2012