DUROFIX RZ4012 Manual de información - Página 14

Navegue en línea o descargue pdf Manual de información para Herramienta eléctrica DUROFIX RZ4012. DUROFIX RZ4012 17 páginas. Oil pulse tool

the switch and should be avoided.
NOTE
When change the position of the forward/reverse lever, making sure the
EC switch is released.
NOTE
The first time the tool is run after changing the direction of rotation, you
may hear a click on start up. This is normal and does not indicate a problem.
Troubleshooting
Check the following before you ask for repair
Situation
Tools Gets Hot
Battery Pack Temperature is
Too High
Battery Pack Temperature is
Too Low
Battery Pack Voltage is Too
Low
Over Current Protection
Fasten torque not reach setting
#1 Press Trigger without
Loading
#2 Pulse Unit is Too Hot to
Shutoff over 5 Sec Fastening
Hydraulic Oil Changing Alert
Setting Torque Reached and
Motor Shut-off Right Away
LED Indicator
RED Steady
Green Blinking
RED Blinking
RED Blinking
Green Steady
RED Steady
RED & Green Blinking
Alternatively
RED & Green Blinking
Simultaneously
Green Blinking for 3 Sec
(If no use lasting 3 min, alert
signal will blink again once
pressing the trigger.)
Green Steady
14
Troubleshooting
Rest the Tool to Room
Temperature
Rest the Battery Pack to Room
Temperature or Change Battery
Pack,
Rest the Battery Pack to Room
Temperature or Change Battery
Pack,
Change Battery Pack and
Charge the Used Pack
Abnormal Shutoff
Release Trigger, then Re-
tightening
Abnormal Shutoff
Release Trigger, then Re-
tightening
Contact Service Centre to
Replace Oil
Normal Shutoff