Installation Instructions for Retrofit Only (continued):
4.
To connect the receptacle on the Recessed Cable Plate with
Recessed Power to the piece of 12/2 or 14/2 with ground UL
approved building wire that you pulled from one opening in the
drywall to the second opening in the drywall, strip off
approximately 3 inches of the outer jack of the UL approved
building wire. Be careful not to cut the jack of the inter wires.
Connect the hot line (black) wire to the brass colored terminal
screw and neutral (white) wire to the silver colored terminal
screw. Be sure to connect the grounding (green) or bare
grounding wire to the green colored terminal screw (see
Figure 3).
5.
Once you have wired the Recessed Cable Plate with Power
receptacle, begin by inserting the receptacle portion of the plate
into the retrofit work box. Once the entire recessed plate is flush
to the wall, using the two white screws supplied, screw the
receptacle portion of the plate to the work box. Next, screw
down the screws with wings. The wings will fasten tightly
against the back of the drywall. Plug all necessary video and
audio cables through the opening on the Recessed Cable Plate
with Power and inside the wall to the opening you cut out for the
Recessed Cable Plate with Straight Blade Inlet.
6.
To connect the Recessed Cable Plate with Straight Blade Inlet to
the piece of 12/2 or 14/2 with ground UL approved building wire,
use the supplied three wire nuts. Connect the hot line (black)
wire to black wire, neutral (white) wire to white wire and
grounding (green) wire to the (green) or bare grounding wire
(see Figure 4). Make sure the three wire nuts are fastened
tightly. Plug all necessary video and audio cables through the
opening on the Recessed Cable Plate with Straight Blade Inlet.
Insert the straight blade inlet portion of the plate into the retrofit
work box. Once the entire recessed plate is flush to the wall,
using the two white screws supplied, screw the straight blade
inlet portion of the plate to the work box. Next, screw down the
screws with wings. The wings will fasten tightly against the back
of the drywall. Make sure to keep your UL approved building
wire away from the video and audio cables (see Figure
2).
(
7.
For shock protection, both the UR, UL recognized receptacle
and inlet components must be properly grounded.
8.
Caution - use copper wire only with this receptacle and inlet.
9.
Install your flat panel TV mounting bracket per the flat panel TV
bracket manufacturer's instructions. Make sure to read all
instructions.
10. The flat panel TV or TV/Projector plugs into the Recessed Cable
Plate with Recessed Power (see Figure 1). The supplied 6 ft.
cord will plug into the Recessed Cable Plate with Recessed
Straight Blade Inlet (see Figure 2) and into either your surge
protector or wall receptacle.
WARNING
OataComm Electronics' products shall be installed and
used only as indicated in OataComm Electronics' product
instruction sheets.
Instruction sheets are available online at
www.datacommelectronics.com.
CAUTION
For shock protection, this device must be properly
grounded.
Use copper wire only with this device.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warning and instructions marked on the product.
Do not use this product near water, for example near a bath
tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.
SAVE THESE INSTRUCTIONS.
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
4-11/16"
)
TEMPLATE
Recessed Cable Plate with Power
&
Recessed Cable Plate
with Straight Blade Inlet
ACTUAL SIZE
CUT ALONG DOTTED LINE X
This product is patent protected by U.S. Patent numbers 0553475, 0554475, 0568719, 11355553 and 7390964.
Multiple patents pending.
~E'''~'
"eifeRM$
T'
O~l.l"'~~US
ULS1D 514C
3026001
C£RI1RED TO
CAR/CSA STO 022.2 NO. 42.1
Page 2 of 2
11/25/08