Feature
Permanent presence or limited presence mode (When presence mode selected. See dip-switch 8)
This setting determines how long the relay remains active when a vehicle is stopped within the sensing loop
Limited presence mode
Permanent presence mode
Relay response 1
Relay response 2
Filter "ON"
Dip Switch settings
(Dip switch 5)
area.
Dip switch 5 "OFF"
Dip switch 5 "ON"
Relay Response (Dip switch 6)
Dip switch 6 "OFF"
Dip switch 6 "ON"
Filter (Dip switch 7)
Dip switch 7 "ON
Description
With limited presence mode, the detector will only
activate the relay for 30 min.
If the vehicle has not moved out of the loop area after
25 min, the buzzer will sound to alert the user that the
relay will deactivate after another 5 min. Moving the
vehicle across the sensing loop area again, will re-
activate the detector for 30 min.
The relay will remain active for as long as a vehicle is
detected within the sensing loop area. When the vehicle
clears the sensing loop area, the relay will deactivate.
Relay activates immediately when the vehicle is
detected in the sensing loop area.
Relay activates immediately after the vehicle leaves the
sensing loop area.
This setting provides a 2 sec delay between detection
and relay activation. This option is used to prevent
false activations when small or fast moving objects
pass through the loop area.
This option can be used where an electric fence nearby
is the cause of false activations.
If the object does not remain in the area for 2 sec the
detector will not activate the relay.
4
ELSEMA
MD2010