1 DEFAULT
Read the RESTORE DEFAULT.
UK
Leggere il codice che ripristina i default.
I
Lecture du code de configuration par défaut.
F
Lesen Sie den Restore Default Code, um die
D
Werkseinstellung wieder herzustellen.
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled;
DATA FORMAT
code length not transmitted, no header, terminator = CR-LF,
character replacement disabled
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, num lock unchanged, inter-
character and inter-code delays disabled, control character
emulation = ctrl+shift+key;
DATA FORMAT
code length not transmitted, no header, terminator =
ENTER, character replacement disabled
POWER SAVE
scan rate 270 scans/s, standby disabled, sleep state
disabled, enter sleep timeout 0.6 sec
READING PARAMETERS
operating mode hand-held, trigger type = hardware, trigger
signal = level, no trigger timeout, Flash On = 1 sec, Flash
Off = .6 sec, one read per cycle, safety time .5 sec, beeper
intensity high, tone 2, beeper type monotone, beeper length
short, good read spot duration medium
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver™ disabled, decoding
safety = one read
RESTORE DEFAULT
: code identifier disabled, no field adjustment,
: code identifier disabled, no field adjustment,