Dataprobe MP-420 Manual de inicio rápido - Página 4

Navegue en línea o descargue pdf Manual de inicio rápido para Hardware de red Dataprobe MP-420. Dataprobe MP-420 8 páginas. Tone controlled power strip with multipal voice response

Models MP-415, MP-420
any control digit if no security code is required. If no control tones are received in 6 seconds, MP-415 will
ring the Extension when no security code is required.
Use the Answer and Prompt Mode if: you want to know exactly when to enter security
and control codes.
If MP-415 is set for security on control only, type 1, the code may be entered when prompted to gain
access to MP-415's control functions. If the correct code is entered, MP-415 will respond "PAL Ready". If
the wrong code is entered, MP-415 responds "Error" and the sender may try once more before the
extension is rung. If MP-415 is set for control and ringing to the extension security type 2, if the wrong
code is entered twice, or no code is entered, the call will be terminated, dropped by MP-415. In the
program mode to set MP-415 for the Answer and Prompt mode, enter 6 plus 1 followed by
Answer And Quiet Mode
MP-415 will answer the call and be quiet for six seconds, waiting for control codes. If none are received
within 6 seconds, MP-415 will ring the Extension.
Use the Answer and Quiet Mode if: You want more secure control of power and the
shortest time before the extension is rung.
If MP-415 is set for security on control only, type 1, the code may be entered during the 6 sec quiet
time to gain access to MP-415's control functions. If the correct code is entered, MP-415 will respond
"PAL Ready ". If the wrong code is entered, MP-415 does not respond, and the extension will be rung.
If MP-415 is set for control and ringing to the extension security, type 2, if the wrong code is entered,
or no code is entered, the call will be terminated, dropped by MP-415. With the right code, MP-415
answers "PAL Ready". To program MP-415 for the Answer and Quiet mode, enter 6 plus 2 followed
'∗'
the
key.
Number of Rings before MP-415 Answers the Call
MP-415 can be set to answer calls after it detects a set number of rings from 1-6. To program the number
of rings, enter 2 followed by the desired number, followed by the
in 4 rings, in the program mode, enter 2 4
if not.
Number of Rings to the Extension
MP-415 can be set to ring the extension a number of times before the call is terminated. Enter 7 plus the
desired number, 1-6 followed by the
Security Mode
(Default = no security)
The security modes are set by entering 5 plus 0, 1, or 2
and 2 for security for all functions, control and extension ring.
Example: to set for security on control only. Enter 51
Setting a Security Code
To program a security code, enter the '#' key followed by up to six number characters, followed by the
'∗'
key. Example; to set a security code of 3451, enter #3451
accepted or Error if not.
'∗'.
MP-415 responds "OK" if the entry was accepted, "Error"
(Default = 4)
'∗'.
Example : 74
(Default = none set)
(Default = 2)
'∗'.
Example . To have MP-415 answer
'∗'.
Will ring extension four times.
'∗'.
0 = no security, 1 for control only,
'∗'.
'∗'.
MP-415 responds
Page 4
'∗'
key.
OK if entry is