Aussie Pumps MINE BOSS SCUD 351 Manual de instrucciones del operador - Página 8
Navegue en línea o descargue pdf Manual de instrucciones del operador para Bomba de agua Aussie Pumps MINE BOSS SCUD 351. Aussie Pumps MINE BOSS SCUD 351 16 páginas.
También para Aussie Pumps MINE BOSS SCUD 351: Manual de instrucciones del operador (16 páginas)
Aussie Pumps
HIGH PRESSURE SPRAY CAN PENETRATE
THE SKIN & CAUSE SERIOUS INJURY!
Never point the spray gun at yourself, other people or
animals.
Should the spray penetrate the skin SEEK MEDICAL
ATTENTION IMMEDIATELY!
F.
Applying detergent
(not available on Predator A)
1.
Prepare pressure washer detergent solution as
required by manufacturer.
2.
Place detergent siphon tub/filter into solution.
3.
Adjust double lance to low pressure setting.
4.
Apply cleaning solution to a dry surface, starting
at lower portion of areas to be washed and
work upward, using long overlapping strokes.
5.
Allow time to detergent to activate and then
rinse off. DO NOT allow detergent to dry on.
IMPORTANT; You must flush the injection system after
each. Place the siphon hose into a bucket of clean
water, then run pressure washer in low pressure for 2
minutes.
UNLOADER SETTING
The high pressure unloader on the machine
is factory set to operate the pump at it's rated
pressure.
DO NOT ADJUST. Tampering with the unloader will
void warranty and can be dangerous.
WORK SMART ... STAY SAFE
8
WARNING:
CHECK NOZZLES AND REPLACE IF WORN
If pressure drops off, check nozzle for wear. Nozzles
should be replaced on a regular basis (every month for
machines in regular use, every 3 months for machines
used intermittently.
incorrect nozzle size or worn nozzle will void warranty
and can be dangerous to the operator.
G.
Stopping the machine
1.
2.
3.
4.
5.
6.
7.
8.
DO NOT RUN EXCESSIVE BY-PASS
SWITCH MACHINE OFF WITHIN TWO MINUTES OF
CEASING OPERATION AS EXCESSIVE BY-PASS CAN CAUSE HEAT
| Aussie Scud Mine Boss (Class A) ... Operator's Instruction Manual
Using the machine with the
If using the detergent injector, flush out the
chemical by running clean water through the
system.
Allow machine to run for 1 minute without load
to cool before stopping.
Turn engine key to OFF
This blaster is fitted with an emergency stop
button. After activation, turn engine key to off
and reset stop button by rotating until it pops
out.
Battery isolator can be locked off to prevent
blaster from operating.
Turn off water supply.
Pull gun trigger to release all pressure in the
system, then LOCK THE TRIGGER.
Hoses may now be disconnected from the
machine.
Failure to release pressure before
disconnecting the hose quick coupler will
result in the quick coupler o-ring seal
blowing out. This o-ring must be
replaced before operating machine.
BUILD UP IN PUMP AND SUBSEQUENT DAMAGE.
EXCESSIVE BY PASS RUNNING VOIDS WARRANTY!!
Jan 2019