4qd BCM-L100 Manual de instrucciones - Página 3
Navegue en línea o descargue pdf Manual de instrucciones para Instrumentos de medida 4qd BCM-L100. 4qd BCM-L100 4 páginas. Battery capacity meter
3.3 Upper / lower percentage values
In sub-section 3, the left 3 digits show the voltage corresponding to 0% capacity,
the right 3 digits show the voltage corresponding to 100% capacity.
Move between the digits with
, when a digit is flashing, increase the value with >,
press and hold
to save and return to the setup menu.
3.4 Alarm function
In sub-section 4 the left side shows if the alarm function is on or off, the right side
shows the voltage below which the warning symbol will flash.
Move between the sections and digits with
, when a digit is flashing, change the
value with >, press and hold
to save and return to the setup menu. Press and
hold > to exit the setup menu if required.
3.5 Calibration.
Connect the meter to an accurate 20V source, enter sub-section 5, press and hold
to calibrate the meter. Press and hold > to exit the setup menu.
4. Dimensions
Length = 61.5mm, width = 33.5mm, height = 13.5mm.
5. Mounting
The BCM-L100 can be clipped into a rectangular slot 58mm x 28mm.
6. Water Resistance
The BCMs are not water proof, the front of the panel is a sealed membrane, but
there are gaps at the rear that should be sealed if water resistance is required.
7. Service
The BCMs are a low cost item and cannot be economically repaired. If the item is
not under warranty it should be replaced.
BCM-L100 V1.0 05/19
Page 3
www.4qd.co.uk