recovery mode for repairing old, idle, stratified or sulfated batteries.
NOT all batteries can be recovered. For optimal results, take the battery
through a full charge cycle, bringing the battery to full charge, before
using this mode. When this mode is chosen, do remember press Mode
button for choosing appropriate 12V/24V Mode(s). One REPAIR cycle can
take up to eight (8) hours to complete the recovery process and will
enter to charge (8 steps charging cycle) when completed. This mode
uses a high charging voltage and may cause some water loss in WET cell
batteries. Plus, some batteries and electronics may be sensitive to high
charging voltages. To minimize risks, disconnect the battery from the
vehicle before using this mode.
Using 13.6V SUPPLY (Hold & Press)
This mode converts the charger to a constant voltage, constant current
DC power supply. When the charger is not connected with battery, it can
be used to power 12VDC devices. Prior to use, read your 12VDC device
manual to determine if it is suitable for use with this mode. As a power
supply, it can also be used to retain a vehicle's on-board computer
settings during battery repair or replacement. 13.6V Supply Mode
provides 13.6V at 9.5A with overload protection at 10A (Max). Both
spark proof and reverse polarity protection are disabled in this mode. Do
NOT allow the positive and negative battery clamp to touch or connect
to each other as the charger could generate sparks.
Using 12V JUMP CHARGE (Press)
USE THIS MODE WITH FULL ATTENTION AS THE CHARGING CURRENT IS
20A. This mode is for 12-volt LEAD_ACID batteries only. To operate JUMP
CHARGE, the charger must be connected to a 12V battery with the
battery clamps connected. Press the Jump Charge button to begin
jumpstarting. For optimal results, allow JUMP CHARGE to complete its
5-minute charge. After 5-minute jumpcharge, the charger will
automatically enter Standby Mode, whether 100% battery level
indicator is illuminated or not, and your are ready to start your vehicle. If
unsuccessful when starting your vehicle, let the battery rest for 15
minutes and try JUMP CHARGE again. Most vehicles will start with one
6