Gaggenau VG 425 211 AU Manual de instrucciones - Página 8
Navegue en línea o descargue pdf Manual de instrucciones para Placa Gaggenau VG 425 211 AU. Gaggenau VG 425 211 AU 16 páginas.
Operating the appliance
en
Individual parts of the burners
Ensure that the individual parts of the burners are fitted
in the correct position and are straight; otherwise, this
may result in ignition problems or problems during
operation.
Fit the burner head and the burner ring in such a way
that the latches on the lower section of the burner click
into place in the corresponding slots. The alignment of
the burner head and the burner ring is not important.
Note: If the burner parts are fitted at an angle, the
appliance will not work.
Individual parts of the standard output burner and
high output burner
(
Burner cap
0
Burner ring
8
Burner head
@
Ignition plug
H
Thermocouple
8
Operating the appliance
N otes
O p e r a t i n g t h e a p p l i a n c e
–
Only use the accessories specified. Do not line the
stainless steel recess (e.g. with aluminium foil).
–
The burner and ignition plug must be clean and dry.
–
Only light the hotplates if the pan supports and all
burner parts are correctly fitted.
–
When one burner is ignited, an ignition spark will
also be generated at all the other burners.
–
Do not touch the ignition plug while the gas
appliance is being lit.
–
It is important to keep the appliance clean. If the
ignition plugs are dirty, this may cause ignition
problems. Clean the ignition plugs regularly with a
small, non-metallic brush. Take care to prevent the
ignition plugs from suffering any heavy knocks.
–
When you switch from setting 3 to setting 4 or
higher, the burner will briefly switch to its maximum
output. This is to optimise ignition between the
burner rings.
–
Do not cover the ventilation openings on the rear of
the gas hob.
–
When the gas cooktop is switched on, the
electronics open up the gas supply, which
produces a short sound. This is normal.
–
In the event of a power failure, the appliance will
not work. The gas supply is shut off.
Abnormal operation
Flames are usually blue and sharply defined. If the
flames are yellowish or noisy or if the gas does not
ignite within the period specified under "switching on"
abnormal operation is indicated. Refer to chapter "After-
sales service" of this manual for service contact details.