Please Note: On the Calibration Results
i
menu, the speed range will be displayed. If
the speed range is too low or too high,
consider changing the range gears on the
metering drive. You will need to perform
new calibration operations across the drill if
range gear adjustments are made. Shown
below.
40. Once the calibration results have been accepted,
the Metering Calibration menu will be displayed.
41. To complete the metering system calibration for
the drill, user will need to complete steps 5
through 40 for each drill section, and then
continue to step 42.
Great Plains | 195-835QS | 03/25/2022
BD7600 Quick Start Guide
42. Once all of the sections on the drill have been
calibrated, tap
calibration menu.
Required System Inputs
The required system inputs within the Metering
System Calibration menus are:
Target Rate
Calibration Factor
Target Rate Increment
Single Hopper Configuration
Split-Box Hopper Configuration
Please Note: Tap the blue field and input the
i
desired value for each field, the system
automatically saves the updated information.
soft key to exit metering