Introduction
FOR RESEARCH USE ONLY
The ValveLink is designed for solution-switching use in research ap-
plications ONLY. AutoMate Scientifi c, Inc. cannot be responsible for
injury or death resulting from medical or pharmacological use.
Hardware Overview
The ValveLink
8 and 16 are simple digital/manual valve con trol lers
™
de signed for use with research automation software. Valves can
be controlled by digital TTL* signals from any I/O card or device.
Eight pushbuttons allow manual user control with eight bi-colored
LED indicators (16 LED's for ValveLink16's plus a 'bank' se lec tor
switch described later). A serial (RS-232) port is pro vid ed for fur-
ther valve control by serial devices. All three input sources (digital,
serial, and push buttons) are si mul ta neous ly active, and the LED's
constantly display the current valve status.
The ValveLink is designed to drive 12 volt DC solenoid valves
plugged into RCA jacks on the back of the box. Why not connect
valves directly to your computer? Several reasons:
1) Most computer interfaces provide +5V signals – not strong
enough to drive most valves (6 to 12V DC and up).
2) Computer interface signals are often too noisy for elec tro -
phys i ol o gy amplifi cation. The ValveLink is designed with
special low noise circuitry to minimize interference with
high-gain amplifi cation.
3) Finally, many solenoid valves are designed to be opened
with a short, full-voltage pulse, then "held-in" with a lower
voltage to keep the valves from heating. The ValveLink au-
tomatically provides dual-voltage hold-in.
* TTL stands for Transistor-Transistor Logic, a +5/0 volt stan dard for representing
on and off – used by the ValveLink for computer valve control.
2
ValveLink Laboratory Applications
Perfusion
A ValveLink can be programmed to precisely switch so lu tions
perfusing over biological samples for physiological re search. The
ValveLink's circuitry is de signed to open valves with low noise for
electrophysiological amplifi cation. Several features, 'Modes' have
been built into the ValveLink for advanced perfusion use.
Washing
Combined with an AutoMate ported washing tray, the ValveLink
can automate washing of electrophoresis gels and blots, and devel-
oping of x-ray or photographic fi lm or prints. You have complete
control over which washing steps of your Western, North ern, South-
ern, Coomassie Blue and Silver staining runs are au to mat ed and
which are han dled con ven tion al ly. Un at tend ed washing can save a
busy lab countless hours of tedious monitoring.
Liquid Chromatography
A ValveLink can be easily programmed to automate solution se-
lection in multi-step ion exchange, gel fi ltration or affi nity chro-
ma tog ra phy runs with excellent reproducibility. The ValveLink
is especially useful in preparative work when a protocol has been
established and programmed to repetitively isolate your valuable
molecule.
Luer lock Valves and Syringe Reservoirs
AutoMate also offers
valves with luer lock fi t-
tings for direct connection
of syringes. This method
eliminates wasted solu-
tion in tubing between
the reservoirs and valves.
Small 2-way stopcocks are
included when this option
is ordered.
3