Great White GW9500 Manual del usuario - Página 8

Navegue en línea o descargue pdf Manual del usuario para Aspirador de piscinas Great White GW9500. Great White GW9500 12 páginas. Automatic pool cleaner

1. Remove swivel assembly (Figure 15) from the top of
the cleaner by turning it 1/4-turn counterclockwise
and pulling straight up on it.
2. Turn cleaner upside down. Remove 4 screws and
remove lower body assembly from shroud.
3 . Turn lower body assembly right side up. Unsnap the
2 clips on the oscillator chamber cap (Figure 16A); lift
it off.
4. Pull the long gear shaft straight up (Figure 16A) by
the blocks on the ends of the shaft. Hold the seals in
the oscillator and the blocks on the shaft. The cam
may interfere with the shaft mounting post; if so, turn
it slightly on the shaft until it clears the post. The shaft
assembly can now be disassembled (Figure 16B).
5. Slide the long gear shaft out of the oscillator (with
gears, complete); make sure that you don't lose the
seals out of the oscillator which may fall out at this
point (Figure 16B).
5A. Oscillator seals are replaceable.
5B. Ratchet gear set and long shaft are replaceable as a
unit.
6. Remove the set screw, short gear shaft, and gears
(Figure 17); do not lose the gears off of the shaft.
7. With a small screwdriver (such as a jeweler's screwdriv-
er), a pencil, or a pen point, depress and remove the coil
spring from the lift brush mounting post (Figure 18).
Replace the brush and the spring if necessary.
8. The metal ratchet tab slides out of its slot sideways;
replace it by removing the center brushes and sliding
in a new ratchet tab until it is flush with the edge of
plastic holder (Figures 19 and 20). Replace the center
brushes.
9. The brush ring pops out of the cleaner body for easy
replacement.
10. If you need to replace the bumper, turn the shroud
and bumber assembly upside down and remove the
two screws holding the bumper to the shroud.
If you have any questions, please call 1-800-752-0183

ABOUT DISASSEMBLY

Figure 15
Long Gear Shaft
Figure 16A
Figure 17
1. Slide metal ratchet tab
toward end of cleaner body
Figure 19
8
Swivel
"Click" at
assembly
this point
3337 1098
Locked
Twist CCW
1/4 Turn
Ocillator
Chamber
Cap
Block
Clip
Cam
Block
1889 0795
Figure 16B
4374 0503
Figure 18
1885 0795
Figure 20
Pull Straight
Up
1887 0795
1886 0795
2. Slide metal ratchet tab
down through cleaner body
1884 0795