SYSTEM OPTIONS *180-*181
✱ 181 50/60 HERTZ AC OPERATION
✱ 182 CONFIGURABLE ZONE TYPE 90
✱ 183 ZONE TYPE 90 REPORT CODES
IMPORTANT: Use existing Contact ID®
codes, if appropriate, or define unique codes
in CID code range 750-789. See important
note in installation instructions.
✱ 184 CONFIGURABLE ZONE TYPE 91
✱ 185 ZONE TYPE 91 REPORT CODES
IMPORTANT: Use existing Contact ID®
codes, if appropriate, or define unique codes
in CID code range 750-789. See important
note in installation instructions.
KEYPAD OPTIONS *190-*196 (NOTE : Options for keypad address 16 are set by the factory and cannot be changed.)
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
∗190 KEYPAD 2 ADDRESS 17
∗191 KEYPAD 3 ADDRESS 18
∗192 KEYPAD 4 ADDRESS 19
∗193 KEYPAD 5 ADDRESS 20
∗194 KEYPAD 6 ADDRESS 21
∗195 KEYPAD 7 ADDRESS 22
∗196
KEYPAD 8 ADDRESS 23
∗197 EXIT TIME DISPLAY INTERVAL
∗198 DISPLAY PARTITION NUMBER
(for Alpha Display Keypads)
∗199 ECP FAIL DISPLAY
[0]
1
2
3
4
Make the appropriate entry for each digit, 1-10, based on the charts provided on the
next page. Each digit's entry is the sum of the values of its selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
90 ALARM ID: XXX
TROUBLE ID: XXX
1
2
3
4
Make the appropriate entry for each digit, 1-10, based on the charts provided on the
next page. Each digit's entry is the sum of the values of its selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
91 ALARM ID: XXX
TROUBLE ID: XXX
[0] [0]
Partition/
Sound
Enable
VISTA-20P: enter partition
VISTA-15P: 1 = enable
0 = disable
[0] [0]
Part./Enable
Sound
[0] [0]
Part. /Enable
Sound
[0] [0]
Part. /Enable
Sound
[0] [0]
Part. /Enable
Sound
[0] [0]
Part. /Enable
Sound
[0] [0]
Part. /Enable
Sound
[0]
[0]
[0]
– 7 –
0 = 60 Hz; 1 = 50 Hz
5
6
7
8
Enter the desired 3-digit Contact ID® report codes for
alarms and troubles occurring on zones assigned to
this zone type. Enter the codes sequentially (all 6
digits). When entering digits, [#] moves cursor back, [∗]
moves forward. Press [∗] when done to continue.
5
6
7
8
Enter the desired 3-digit Contact ID® report codes for
alarms and troubles occurring on zones assigned to
this zone type. Enter the codes sequentially (all 6
digits). When entering digits, [#] moves cursor back, [∗]
moves forward. Press [∗] when done to continue.
Partition: 0 = keypad disabled; 1-3 = part. no. (3 = com)
Sound:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime
beeps
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
See field ∗190 for entries.
† VISTA-20P: enter partition
VISTA-15P: 1 = enable; 0 = disable
0 = no display; 1-5 = seconds between display refresh
0 = no; 1 = yes (partition no. appears on Alpha Display)
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
9
10
9
10