Instruction Manual
SETUP Menu Operation
DISPLAY
SETUP
S12:00P
MENU button
DEG F
MENU button
MIN 6
MENU button
MAX 40
MENU button
CFT 8
MENU button
IGN N
Automation Correct LLC
Coal-trol Digital™ - Model TS2 V3
ACTION
Press and hold the MENU
button for 3 seconds until
SETUP is shown on the
display.
SET Time of Day Clock
S1132A
UP button
DOWN button
SET the Temperature Units
DEG C
UP button
DOWN button
Minimum Stoker Feed
MIN 7
UP button
DOWN button
Maximum Stoker Feed
MAX 44
UP button
DOWN button
Convection Fan Threshold
Maximum setting = 30.
CFT 15
UP button
DOWN button
Enable Igniter Features
IGN M
UP button
DOWN button
The SETUP menu is for initial setup. Once done, these
settings need not be adjusted. Except for the time of day
clock, the settings are maintained in the thermostat.
5/2010 R0
Page 11
NOTE
The word "SETUP" is displayed for
only 1 second and then the display
shows the Time of Day setting.
Display shows "S" for SET. After
extended power loss, the time of day
setting may be adjusted without entry
into SETUP menu.
Press UP button for Deg. C or the
DOWN button for Deg. F temperature
units.
MIN feed value cannot be increased
beyond the MAX feed value. Too low
a value can allow the fire to go out.
This setting does not automatically
return to the Round-robin display.
MAX feed value cannot be decreased
below the MIN feed value. Make sure
that coal is completely burned out
about 1-2 inches from end of grate.
This setting does not automatically
return to the Round-robin display.
When the firing rate (FR) percent is
greater than the (CFT) percentage,
the convection blower will be allowed
to start. Use this to increase the
temperature of the convection air at
low firing rates. (There may be up to a
9 minute delay between when the FR
indicator is greater than CFT and the
fan actually starts, as the Coal-trol
waits for the stove temperature to
i n c r e a s e b e f o r e s t a r t i n g t h e
convection blower.)
Advanced setting to enable Igniter
features. "N" for No, "M" for Manual.