Automation Correct Coal-trol Digital TS2 V3 Manual de instrucciones - Página 12
Navegue en línea o descargue pdf Manual de instrucciones para Termostato Automation Correct Coal-trol Digital TS2 V3. Automation Correct Coal-trol Digital TS2 V3 16 páginas.
Instruction Manual
MIN/MAX Adjustment
The Coal-trol Thermostat uses the values set by MIN and MAX as limits to determine the minimum and
maximum fire size allowed on the grate. The factory settings for your stove should be the starting point
for any adjustment. The need for large adjustment from the factory default settings may indicate
mechanical problems with the stove that will not be solved by MIN/MAX adjustment.
While displaying MIN or MAX, the Coal-trol Digital runs the stoker at the MIN or MAX value and NOT
according to desired room temperature. When finished making a MIN or MAX adjustment, press the
MENU button to return to the Round-robin display which resumes normal thermostatic control.
To adjust the Minimum feed rate go to MIN and observe the fire. Allow the fire to "settle into" its
minimum firing rate. Adjust MIN to the desired fire size. Allow enough time between adjustments for fire
to settle in to a new value. MIN values typically range between 2 and 12, If MIN is set too low, the fire
can go out.
To adjust the Maximum feed rate go to MAX and observe the fire. Allow the fire to "settle into" its
maximum firing rate. Adjust MAX to the desired fire size. Allow enough time between adjustments for
fire to settle in to a new value. MAX values typically range between 17 and 85. If MAX is set too high
partially burned coal may be driven off the grate into the ash-pan. Coal should be completely burned
about 1 to 2 inches from the end of the grate.
WARNING - The Coal-trol Digital™ is capable of regulating a coal fire smaller than required to
maintain proper chimney draft. Follow all manufacturers recommendations for minimum draft
pressures and temperature. The use of mechanical means such as a draft inducer fan may be
required to ensure proper draft at low fire. Installation of a carbon monoxide detector (not-
included) is highly recommended.
SETUP Menu Settings and Mechanical Adjustment
This table contains the TS2 thermostat settings as shipped from the factory and typical settings for
various stove models. The "MECHANICAL" setting is adjustment needed for your stove mechanism.
Setting
Display
Clock
S
Temperature
DEG
Units
Minimum
MIN
Feed Rate
Maximum
MAX
Feed Rate
Convection
Fan
CFT
Threshold
Igniter
Features
IGN
Enable
Mechanical
Automation Correct LLC
Coal-trol Digital™ - Model TS2 V3
Keystoker
Factory
90/105/
Value
Koker
12:00P
adjust
F
F
6
10
40
85
8
8
N
N
Set Feeder
Screw full
clockwise
Reading
Reading
(separate
(Tri-burner)
combustion
blower)
adjust
adjust
F
50
99
24
8
N
Set red nut to
Set red nut
tight against
to 5/8" from
acorn nut, then
acorn nut.
back off 2 turns.
5/2010 R0
Page 12
Alaska
(paddle)
adjust
F
F
3
4
30
8
8
N
N
www.automationcorrect.com
Harman
(Magnum)
adjust
F
6
99
8
N
Set
adjustment
handle to
11/16" from
acorn nut