Automation Correct Coal-trol Digital TS2 V3 Manual de instrucciones - Página 14

Navegue en línea o descargue pdf Manual de instrucciones para Termostato Automation Correct Coal-trol Digital TS2 V3. Automation Correct Coal-trol Digital TS2 V3 16 páginas.

Instruction Manual
Room Over-Temperature Cutout
DISPLAY
HiTemp
STOP

Maintenance and Troubleshooting

The Coal-trol Digital System is only the command and control piece of a properly operating stove. If the
Control Module power light is ON, and the Thermostat is displaying normally, the easiest way to
determine the source of an electrical or mechanical problem is to go to TEST mode and observe for
proper operation of the controlled item.
Problem
Power Light on Control
Module is not ON
Thermostat has no display.
Fire goes out now, but was
working before.
Hot coals falling off of grate.
Automation Correct LLC
Coal-trol Digital™ - Model TS2 V3
ACTION
The STATUS indicator light
blinks every second.
CAUTION: Before proceeding,
investigate the cause of the
over-temperature condition.
Press the MENU button to
Reset.
Possible Cause(s)
1) No power to Control Module.
2) Fuse blown in Control Module.
1) No power to Control Module.
2) Cable not snapped in.
3) Bad cable.
1) Stoker mechanism jamming or
dragging.
2) Hopper clogged or empty.
3) Stoker motor defective.
4) Combustion blower defective.
1) MAX set too high.
2) Control problem.
Check power.
Turn Power switch ON.
Replace fuse.
Bad Motor or bad wiring.
Bad Control Module.
Check power.
Snap in both ends of cable.
Replace cable.
Bad Thermostat.
Bad Control Module.
Go to TEST mode and verify that the
Stoker motor and Combustion blower
are working.
Troubleshoot mechanicals.
Verify fuel quality and sizing.
Bad control cable.
Bad Thermostat
Bad Control Module.
1) Go to TEST mode and verify that
the Stoker motor and Combustion
blower are working properly. If not,
replace Control Module.
2) Perform MAX/MIN adjustment.
5/2010 R0
Page 14
NOTE
The temperature sensor in
the thermostat has detected
a room temperature above
97°F/36°C and has disabled
all the controlled motors.
The HI TEMP display may
indicate a problem with your
stove, chimney, or Coal-trol
Digital System.
The thermostat will not allow
the MENU button to reset
the thermostat until the room
temperature is less than
96°F/35.5°C
Possible Solution(s)
www.automationcorrect.com