Autonics LE4SA Instrucción - Página 13
Navegue en línea o descargue pdf Instrucción para Timer Autonics LE4SA. Autonics LE4SA 18 páginas. Din w48xh48mm digital backlight lcd timer
También para Autonics LE4SA: Manual (17 páginas)
LE4S Series
LE4S Output operation mode
Mode
Time chart
[
INT
]
INT
Interval
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. When RESET signal is ON, display value and output will be reset.(① position)
T > Ta
4. If RESET signal is OFF when START signal is ON,"STEP 1" will be restarted.
5. When START signal is OFF, display value and output will be reset.(② position)
INt1
[
]
INTⅠ
Interval 1
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. Even though START signal is applied repeatedly, only the initial signal is recognized.(① position)
4. If START signal is ON after timing operation is progressed up to the setting time, Output will be ON and setting
T > Ta
5. When RESET signal is ON, display value and output will be reset.(② position)
[
NFD
]
ON OFF D
ON-OFF Delay
1. If START signal is ON when power is on, Output will be ON when timing operation is progressed up to the Ton
2. If START signal is applied repeatedly, output is ON and display value will be reset.(① position)
3. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta
4. It is able to set each Toff time and Ton time separately.
NFd1
[
]
ON OFF DⅠ
ON-OFF Delay 1
1. If START signal is ON when power is on, timing operation starts. Output will be ON when timing operation
2. Output will be ON when START signal is ON and goes OFF during setting time and display value will be reset.(① position)
3. Output will be OFF when START signal is OFF and goes ON during setting time and display value will be reset.(① position)
4. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta
5. It is able to set each Toff time and Ton time separately.
[
OFD
]
OFF D
OFF Delay
1. If START signal is ON when power is on, output will be ON.
2. When START signal is OFF, timing operation starts. Output will be OFF when timing operation is progressed up
T > Ta
3. When RESET signal is ON, display value and output will be reset.
※ Initial status : UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
K-32
T
POWER
START
RESET
RELAY OUT
Set time
UP
0
Set time
DOWN
0
T
POWER
START
①
RESET
RELAY OUT
Set time
UP
0
Set time
DOWN
0
time will be reset and then timing setting starts.
Ton
Toff
POWER
START
RESET
RELAY OUT
Toff
Ton
UP
0
Toff
Ton
DOWN
0
setting time(On-Delay). IF START signal is OFF, output will be ON when timing operation is progressed up to
the Toff setting time (OFF-Delay).
signal is ON, it will be operating as On-Delay.(② position)
Ton
Toff
POWER
START
RESET
RELAY OUT
Toff
Ton
UP
0
Toff
Ton
DOWN
0
is progressed up to the Ton setting time(On-Delay). IF START signal is OFF, output will be ON when timing
operation is progressed up to the Toff setting time (OFF-Delay).
signal is ON, it will be operating as On-Delay.(② position)
Ta
POWER
START
RESET
RELAY OUT
Set time
UP
0
Set time
DOWN
0
to the setting time. Display value will be HOLD.
T
Ta
②
①
Ta
T
T
Ta Ta
Toff
Ta
Ton
①
②
Ta Ta
Toff
Ta
Ton
①
②
T
Ta
T = Setting time, T > Ta
Operation
T
POWER
START
RELAY
T = set time
T
②
POWER
START
RELAY
T = set time
Ta
Ton
Toff
POWER
START
RELAY
OUT
Ton, Toff = set time
Ta
Ton
Toff
POWER
START
RELAY
OUT
Ton, Toff = set time
Ta
T
POWER
START
RELAY
OUT
T = set time
T
OUT
T
T
OUT
Ton
Toff
Ton
Toff
T