activTek INDUCT 5000 Manual - Página 14
Navegue en línea o descargue pdf Manual para Limpiador de aire activTek INDUCT 5000. activTek INDUCT 5000 16 páginas. Electronic air purification system
También para activTek INDUCT 5000: Manual (16 páginas)
REPLACING ThE BALLAST
Replacement of the Ballast may be necessary if after replacing the ActivePure Cell(s) the
lamp still does not become active.
CAUTION: NEVER ATTEMPT TO CHECK OPERATION OF THE
ACTIVEPuRE CELL(S) BY DIRECT OBSERVATION. SEVERE EYE DAMAGE
CAN RESuLT. uSE THE INDICATOR LAMPS ON THE BOTTOM OF THE
Note: Disconnect power at the breaker or fuse panel before servicing unit.
1
1. Disconnect power at the breaker or
fuse panel before servicing unit.
3
3. Remove the two (2) nuts on the
top and bottom side of the ballast
to pull ballast from assembly.
2
2. Open the ballast housing by
removing the four (4) screws
then removing cover.
4
4. Remove the wires (activTek
INDUCT 10000 - 8 wires, INDUCT
5000 - 6 wires) from ballast by
pressing a small screwdriver into
the wire release.
wire release
9