Running an EDID Capture
Before using the Isolator, run a one-time EDID capture on both sides – Transmitter and
Receiver. This prevents the continuous transfer of potentially malicious data - from the
display to the PC – that could infect the PC, cause data leakage, and so on.
Preparation:
Connect the PC and all peripherals to both the units, according to the
diagram.
Make sure the PC, display, and the units are ON.
To run an EDID capture:
1.
On the Transmitter, short-click the CAPTURE button – for less than one
second.
Warning: Long-clicking the CAPTURE button sends the unit into an
undesired loop. If this happens, restart the unit and repeat the
procedure.
At first, the EDID LED flickers for a few seconds and then lights
continuously.
2.
Make same on the Receiver, short-click the CAPTURE button – for less
than one second and wait until the EDID LED will light continuously.
Note: If the EDID LED is OFF, check the connections and that the PC or
the Display are powered ON. Then, repeat the procedure.
3. Restart the both units.
Secure Extended Isolators Quick Setup Guide
2
1
EDID
Lock/Capture
3
Note: An EDID capture needs to be
performed for new installations and
when changing a display.