SECTIONS

OPERATION

Running an EDID Capture
Before using the Isolator, run a one-time EDID capture on both sides – Transmitter and
Receiver. This prevents the continuous transfer of potentially malicious data - from the
display to the PC – that could infect the PC, cause data leakage, and so on.
Preparation:
Connect the PC and all peripherals to both the units, according to the
diagram.
Make sure the PC, display, and the units are ON.
To run an EDID capture:
1.
On the Transmitter, short-click the CAPTURE button – for less than one
second.
Warning: Long-clicking the CAPTURE button sends the unit into an
undesired loop. If this happens, restart the unit and repeat the
procedure.
At first, the EDID LED flickers for a few seconds and then lights
continuously.
2.
Make same on the Receiver, short-click the CAPTURE button – for less
than one second and wait until the EDID LED will light continuously.
Note: If the EDID LED is OFF, check the connections and that the PC or
the Display are powered ON. Then, repeat the procedure.
3. Restart the both units.