TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Adjustable Temperature Range (°C)
Minimum Temperature Differential (between the supply and the outlet temperature) (°C)
Factory Set Thermostatic Temp. (°C)
Maximum Static Pressure (kPa)
Minimum Flow Rate for Stable Outlet Temperature (LPM)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
Table 1. Technical Information
5.0

WATER SUPPLY CONDITIONS

INTRODUCTION
®
This CliniMix
CP-BS Hob
Mounted Thermostatic Progressive Basin Mixer - Lever
standards. When installed the supply conditions detailed below must be observed.
SUPPLY REQUIREMENTS
This mixer is designed to be installed on all types of plumbing systems.
Hot and cold water supply pressures should be reasonably balanced; however, the mixer will function within
specification on unequal pressures up to 10:1.
The mixer has integral isolating valves which permit servicing of the strainer, check valve/flow regulator and
thermostatic cartridge. They are also used for thermal disinfection.
The minimum pressure for the correct thermal operation is 20kPa. However, to achieve an acceptable flow
performance at very low pressures it may be necessary to remove the combined check valve and flow
regulators and replace them with simple check valves.
Supply Water Temperature Range (°C)
Maximum Static Pressure (kPa)
Working Pressure Range (kPa)
Permitted Supply Pressure Variation
Table 2. Water supply conditions
*Tapware must be installed in accordance with the provisions of AS/NZS 3500. Installations not complying with AS/NZS 3500 may void the
product and performance warranty provisions.
Min
Max
Min
Max
Min
Max
3
Version 2, 29 May 2020, 3 of 18
½" BSP – Female
Flow Straightener
Thermostatic
mixing valve
20
500
5
85
35
48
10
41
1000
6
8
Chrome
is manufactured to the highest
Min
5
Max
85
1000
Min
20
Max
500*
10:1