Galvin Engineering CliniMix CP-BS WM-TMVPMB Manual de instalación del producto - Página 5

Navegue en línea o descargue pdf Manual de instalación del producto para Productos de fontanería Galvin Engineering CliniMix CP-BS WM-TMVPMB. Galvin Engineering CliniMix CP-BS WM-TMVPMB 18 páginas. Hob mounted thermostatic progressive basin mixer - lever

Galvin Engineering CliniMix CP-BS WM-TMVPMB Manual de instalación del producto
3. Install supplied isolating valves to wall spouts.
Unscrew the non-return valves/strainers from the
flexible hoses and screw them down on the
insolating valves. Attach flexible hoses to the tap
and connect to hot and cold water supply,
ensuring they correspond to the markings on the
bottom of the tap.
6.2
HANDLE POSITIONING
1. Fully open valve (anti-clockwise).
2. Remove the handle assembly. To prevent damage,
carefully prise off plastic indicator from the handle.
(Use a small flat bladed screwdriver if necessary).
Use 4mm Hex key to remove holding screw.
4. Fit handles screw & tighten with a 4mm Hex Key.
Finally, fit cover cap to handle.
4. Turn the mixer on and test operation. Commission as
per instruction.
3.
Refit handle onto spline as shown.
5.
Rotate handle clockwise to closed position. Handle
should stop in approximate position shown.
5
Version 2, 29 May 2020, 5 of 18