Gree XK41 Manual técnico del producto - Página 8

Navegue en línea o descargue pdf Manual técnico del producto para Controlador Gree XK41. Gree XK41 11 páginas. Command center for ductfree split systems
También para Gree XK41: Manual del usuario (19 páginas), Manual del usuario (2 páginas)

Gree XK41 Manual técnico del producto

INSTALLATION

The following is a brief XK-19 and XK-41 Wired Tether
Controller installation overview. See Wired Controller
Installation Manual for more detailed instructions on
installation, start-up, and setup.
Connecting Indoor Unit
Select a proper location on the wall for mounting
the Tether Controller. Install switch box, if required
by code. Locate the 26-ft communication cable that
came with the Tether Controller. Run communication
cable (as desired) between indoor unit and selected
wall mounting location. Locate the Tether Controller
connector in the control box area of the indoor unit.
Carefully connect communication cable to indoor unit.
Wired Tether Controller Installation
Pull communication cable through switch box (if
one is used) and Wired Tether Controller backplate.
Securely fasten backplate to the switch box or wall.
Carefully connect communication cable to rear of
Wired Tether Controller panel. Push extra cable into
wall and secure controller panel to backplate mounted
on the wall.
NOTE: Do not cut and splice communication cable.
Follow the start-up setup instructions supplied with
the Wired Tether Controller.
7