Gamma 5003 Manual del usuario - Página 13

Navegue en línea o descargue pdf Manual del usuario para Máquinas de encordar Gamma 5003. Gamma 5003 19 páginas. 6 point mounting
También para Gamma 5003: Manual del usuario (20 páginas), Manual del usuario (20 páginas), Manual del usuario (20 páginas)

Gamma 5003 Manual del usuario

TENSION CALIBRATION

Tension Calibration Procedure
Step 1
Set the tension to 60 lbs. as indicated by the linear scale
and rotary knob. Place the string on one end of a tension
calibrator into a string clamp and secure. Place string
located on the other end of the calibrator into the string
tensioner and apply tension. If the brake lever releases
before 60 lbs. or after 60 lbs., the tension head should be
calibrated as follows.
Step 2
Loosen the 1.5 mm locking set screw (A) located on the
side of the latching block as shown. The set screw is
used to hold the adjustment screw in place.
A
Step 3
B
If the lever releases before 60 lbs., using the supplied L-
shaped hex wrench, turn the adjustment screw (B)
located on the left side of the latch block counter-
clockwise to increase the engagement of the brake
release latch with the brake lever. Repeat step 1 and
adjust until the correct tension is indicated on the calibra-
tor.
If the tension indicated in step 1 is greater than 60 lbs.,
turn the adjustment screw clockwise to reduce the
engagement of the brake release latch with the brake
lever. Repeat step 1 and adjust until the correct tension
is indicated on the calibrator.
12