6. 0PERATING
WARNING: Do not connect the unit to live voltage.
6.1. Calibration Procedure
1. Each time the meter is turned ON, it should be calibrated before use.
2. Set the rotary switch from the OFF to O Position.
3. Connect the two leads for the red set of Kelvin clips are plugged into
the red terminals on the meter; Connect the two leads for the black set
of Kelvin clips are plugged into the black terminals on the meter.
Note: Make sure the calibration bar and Kelvin clips jaws are clean.
4. Connect the two alligator clips to the supplied copper rod, move the
clips as close together as possible.
6 8
Make sure that the clips are as close together as
possible in order to improve calibration accuracy.