Jalo Helsinki Kupu Manual
Navegue en línea o descargue pdf Manual para Alarma de humo Jalo Helsinki Kupu. Jalo Helsinki Kupu 2 páginas.
SMOKE ALARM MANUAL ENGLISH
KUPU
Contents
1.Read this before you install
2.Locations
3.Installation
4.Operation
5.Maintenance
6.Technical data
7.Service & Warranty
EN 14604:2005
0832-CPD-1674
P/N 00061
1. Read this before you install
Thank you for purchasing a Jalo smoke alarm. To ensure maximum safety for
you and your family please read all the instructions before you install the smoke
alarm.
If you install this smoke alarm for someone else you must leave this manual or
a copy of it with the end user.
This smoke alarm is suitable for use in leisure accommodation vehicles (LAV)
such as caravans and boats.
2. Locations
Recommended Locations
alarm in every bedroom and corridor. Smoke alarms should be placed in the
Place a smoke alarm at the top of every stairway.
Avoid these locations Near the wall or the corner Do not install the smoke alarm
within 50 cm from a wall or a corner.
Humid places
Avoid installing the smoke alarm in a location near a shower or a kitchen,where
vapors or fumes may cause false alarms.
Air vents
may prevent the smoke from reaching the detection chamber of the alarm.
Insect infested places
Avoid installing the smoke alarm in a location which is insect infested. Insects
could clog the openings of the detection chamber.
Dead air places
If you have a peaked ceiling, install the smoke alarm at least 10 cm lower than
the peak of the ceiling.
Fluorescent lights
3. Installation
This smoke alarm can be installed in two ways: (1) fast installation with 3M
double-sided adhesive tape or (2) with the screws provided in the package.
Please note that the mounting plate does not attach to the main unit if batteries
are not installed properly or they are missing!
Installation guide is on the other side of this manual.
4. Operation and testing This smoke alarm uses a photoelectric detection
method.
Test your smoke alarm every week by pressing down the front surface for about
3 seconds until the alarm siren starts. The entire surface of the smoke alarm
functions as a test button.
The alarm noise level is 85 dB at a three meter distance from the device.
If your smoke alarm malfunctions, please contact your distributor or the manu-
barcode next to the battery compartment.
1050a/01
.
Silence function
Use the silence function if the smoke alarm is exposed to cooking fumes or
false alarms. When the alarm siren is on press down the smoke alarm's front
surface for 3 seconds until the alarm sound stops. The smoke alarm will then go
over to the silent mode for approximately eight minutes. After eight minutes the
smoke alarm will return to the normal operation mode. Note that if an alarm is
caused by very thick smoke, the alarm siren will continue despite the use of the
silence function.
Operation
Test mode
Low-Battery
mode
mode
Sound
Two chirps
One short
per second
chirp every 30
followed by a
seconds.
two second
pause.
Indicator Led
every 30
every second.
every 30
seconds.
seconds.
Operational
Normal opera-
The smoke
Flash and chirp
alarm enters the
tion mode
at the same
test mode after
time
pressing the
whole surface
button down for
3 seconds. The
device enters
the silence
mode if button
is pressed down
longer than 3
seconds.
5. Maintenance
Test your smoke alarm every week
Test your smoke alarm by pressing down the cover for 3 seconds. You should
hear a couple of chirps.
Battery replacement
The smoke alarm contains three 3V lithium batteries (IEC-CR2450). Their
service life is approximately 5 years. When the batteries are running low, the
smoke alarm will produce an alarm sound approximately every 30 seconds, run-
ning for at least 30 days. Please change the battery as soon as possible.
Recommended battery brands:
MALAK CR2450 Lithium Cell 3V
ENERGIZER CR2450 Lithium Cell 3V
SONY CR2450 Lithium Cell 3V
rest batteries by turning the smoke alarm upside down and shaking it gently.
Look up the terminal sign of the new batteries and put them into the chamber
in such way that minus sign faces the minus sign terminal at the bottom of the
chamber. Install rest of the batteries in the same way on top of each other.
WARNING: Lithium batteries can explode or cause burns if not installed prop-
erly. Use only recommended battery type and brands.
After changing the batteries always test the performance of the smoke alarm.
If the smoke alarm doesn't work correctly after the battery changing please
contact the manufacturer.
The mounting plate does not attach to the main unit if batteries are not installed
properly or are missing!
Clean your alarm at least once a year
Take off the smoke alarm by turning it counterclockwise. Vacuum clean the main
unit of the smoke alarm gently. After cleaning press the HUSH button at the
back of the main unit and reinstall your alarm. Always test it after cleaning.
Do not modify or paint the smoke alarm.
Disposal
The smoke alarm should be disposed as normal electronic waste. Follow your
local guidelines on how to dispose electronic waste.
6. Technical Data
Voltage of 9V Noise level 85dB / 3 meters Power consumption 15mA Operating
Temperature 0°C – 45°C Humidity Max 90% (RH) Adhesive tape holding temp.
-35°C – 93°C
7.Warranty
Jalo Helsinki smoke alarms have a 5 year warranty starting on the date of
purchase. If defects or faults should appear in the smoke alarm during the war-
ranty period, the product will be repaired or exchanged for a new one when sent
to Jalo Helsinki Ltd. The warranty covers manufacturing, design and material
defects when the smoke alarm has been operated according to the instructions
provided in the manual and the warranty period has not expired. If the smoke
alarm or some parts of it are exchanged during the warranty period their war-
ranty expires on the date of the original warranty date.
The warranty will be void if the product is not used, maintained or tested in
accordance with the instructions, if the damage or defect is due to wilful neglect
or negligence by anyone other than Jalo Helsinki Ltd, if the product has been
altered, the product has been treated violently or the customer does not have
a receipt for the purchase. The warranty does not cover batteries or setup costs.
Jalo Helsinki Ltd liabilities on the sale of the smoke alarm will in no case exceed
the equivalent to a cost of a new smoke alarm. Jalo Helsinki Ltd is not respon-
sible for any loss or damage caused by a malfunctioning smoke alarm, even
when the loss or damage could be the result of a malfunctioning smoke alarm
or an omission by the manufacturer. This warranty shall not have an effect on
consumer rights in respect of Consumer Protection Law or in respect of the
purchase agreement between the consumer and the distributor.
Manufacturer
Jalo Helsinki Ltd. P.O Box 131, 00181 Helsinki Finland
Copyright 2010 Jalo Helsinki Ltd. All rights reserved. Jalo is a registered trade-
mark of Jalo Helsinki Ltd. RCD 001707050.
Importer Segula GmbH, 50969 Köln www.segula.de
Fault mode
Silence mode
Alarm mode
One short
Three loud
chirp every 30
chirps followed
seconds.
by two second
silence.
every 30
every eight
every second
seconds.
seconds.
Flash and
The smoke
The smoke
chirp have 15
alarm enters
alarm enters
second differ-
the alarm mode
the silence
ence.
mode after
if smoke is
pressing down
detected.
the whole
surface button
for longer than