Gas connection
Warning! Only a qualified
person must install this
appliance.
Warning! This appliance is not
connected to a combustion
products evacuation device.
Installation must comply with current local
regulation.
The connection of the cooktop to the gas
pipe network or gas cylinder must be made
by means of a rigid copper or steel pipe
with fittings complying with local
regulations, or by means of a continuous
surface stainless steel hose complying with
local regulations.
If you see any abnormalities do
not repair the pipe, contact local
After Sales Service (refer to the
Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas.
Warning! Once the installation is
complete, check the perfect seal
of every pipe fixing. Use soapy
water, never flame.
Electrical connection
The electrical work necessary to install the
appliance must be done by a qualified
electrician or competent person, according
to the current regulations
Before connecting, check that the nominal
voltage of the appliance stated on the
rating plate, corresponds to the available
supply voltage. Also, check the power
rating of the appliance and ensure that the
wire is suitably sized to suit the appliance
power rating (refer to the Technical
information chapter).
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with a
minimum gap of 3 mm between the switch
contacts. The double pole has to be of a
type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
90 °C temperature. The blue neutral cable
must be connected to the terminal block
marked with "N". The brown (or black)
phase cable (fitted in the terminal block
contact marked with "L") must always be
connected to the live phase.
The rating plate is located on the lower
casing of the hob.
Replacement of the connection cable
Warning! The replacement of the
connection cable requires the
specific equipment of a
technician.
15