Gardena 4000/5 Manual de instrucciones - Página 4

Navegue en línea o descargue pdf Manual de instrucciones para Césped y jardinería Gardena 4000/5. Gardena 4000/5 17 páginas. Garden pump
También para Gardena 4000/5: Manual de instrucciones (10 páginas), Manual de instrucciones (17 páginas), Manual de instrucciones (12 páginas), Manual del usuario (14 páginas), Manual del usuario (11 páginas), Manual del usuario (10 páginas), Manual de instrucciones (18 páginas), Manual del usuario (10 páginas), Manual de instrucciones (19 páginas), Manual de instrucciones (13 páginas)

Gardena 4000/5 Manual de instrucciones
Note
v Protect the pump from rain. Don't use the
pump in wet or moist area.
In order to avoid dry-running of the pump, take
care that the end of the suction hose is always
submerged into the liquid.
v Before each operation, fill the pump to over-
flowing with approx. 2 to 3 l of the liquid to be
pumped!

3. Initial Operation

Setting up your Garden Pump:
Connecting hose to
suction side:
2
1
Sand and other abrasive substances in the liquid
cause in-creased wear and reduce the pump's
output.
Pumping dirty water, e.g. stones, pine needles
etc., can cause damage to the pump.
v Do not pump dirty water.
The minimum flow rate is: 4000/5: 90 l/h
(= 1.5 l/min); 5000/5: 200 l/h (= 3.3 l/min).
Watering accessories with lower rate must not
be operated.
The site must be firm and solid in order to ensure safe and sturdy
operating conditions for the pump.
v Position the pump at a safe distance (min. 2 m) from the liquid
to be pumped.
The pump must be installed in a location with low air humidity
and sufficient ventilation in the area of the ventilation slots.
It must be at a distance of at least 5 cm from the walls.
No dirtcontamination (e.g. sand or earth) may be sucked in
through theventilation slots.
Don't use any hose connection system fittings on the
suction side! A vacuum-resistant suction hose must be used,
e. g. GARDENA Suction Unit, art. no. 1411.
In order to reduce the suction time, it is advisable to use a suction
hose with backflow preventer avoiding automatic draining of the
suction hose when the pump is stopped.
1. Screw a vacuum-resistant suction hose
connector on the suction side of the pump
2. For suction heights exceeding 4 m also secure the suction
hose
(e.g. by fastening it to a wooden post).
1
This relieves the pump of the weight of the suction hose.
airtight onto the
1
.
2
15