Gardena 5700 Manual de instrucciones - Página 6
Navegue en línea o descargue pdf Manual de instrucciones para Césped y jardinería Gardena 5700. Gardena 5700 10 páginas. Power scrubbing brush
6. Putting into operation
Attention !
Delivery condition
Working with high pressure !
from the manufacturer
For safety reasons, the
A
motor starts only when
C
the operating lever
for the
gun is pressed down. The
Position "MIX"
D
safety knob
is exclusively
for prevention of unintentional
use, and not to be used to lock
C
the operating lever
during
The concentration of cleaning
operation.
agent can be regulated as
required.
6.1 Operation using one of
Replacing cleaning rings
the nozzles (fig. H / J)
1. Plug the mains connector
The cleaning rings
into a 230-V a / c socket outlet.
can be replaced
2. Open the water tap.
in this position.
3. Set the dispensing
unit adjust-
Setting the mix ratio (fig. K)
ment knob to
this position:
4. Switch the equipment on:
Turn the ON / OFF switch
required within the range of this
to position I (fig. H).
symbol (fig. K). The cleaning rings
5. Unlock the high-pressure pistol
can be used with all of the tools
D
(press safety knob
) and
supplied and mixed into the water
press the high-pressure pistol
at any working pressure. The
C
operating lever
(fig. J).
mixing pot is transparent so that
the cleaning ring consumption
6.2 Adjusting the Vario nozzle
is visable.
(fig. I)
Inserting cleaning rings (fig. K)
The Vario nozzle can be adjusted
The GARDENA Power Scrubbing
to any position, from a hard jet
Brush is fitted with a dispensing
to a flat jet of water. Turn the
unit. Cleaning rings can be in-
nozzle to set the jet required, as
serted as follows:
indicated by the direction of the
1. Turn the adjusting
arrow shown in figure I :
knob on the dis-
Flat jet in the clockwise direction
pensing unit to
(fig. I 1)
this position:
Hard jet in the anticlockwise
direction (fig. I 2)
A
Please read section 6.6 on termi-
in this position ! There is a
nating work.
danger of damaging the unit.
2. Unscrew the dispensing cup
6.3 Working with cleaning
from the dispensing unit.
rings
3. Place cleaning rings in the
dispensing cup.
Operating the dispensing unit
4. Screw the dispensing cup
(fig. K)
back onto the dispensing unit.
The dispensing unit has 3 main
5. Turn the adjusting knob
positions which can be set as
on the dispens-
follows:
ing unit to
this position:
16
6.4 Switching on for working
(fig. C)
Water throughput
Hold the high-pressure gun, pre-
without the addition
ferably with both hands as shown
of cleaner.
in figure C. Hold the handle with
the operating lever
pressure gun with one hand and
This position will
guide the direction of the high-
dispense cleaning
pressure gun with the other hand.
agent.
6.5 Working with the power
scrubbing brush
The power scrubbing brush is
suitable for cleaning dirty surfaces
such as e.g. tiles, natural stone
slabs, concrete slabs etc. without
the use of water jets. For easier
handling there are 2 working
positions possible (each turnable
180°).
The mixing ratio
cleaner / water can
Adjusting the working
be adjusted as
positions (fig. L)
To change the working position
proceed as follows:
1. Unscrew the upper nut
extension handle.
2. Pull the power scrubbing brush
with adaptor out of the bayonet
socket and turn it 180°.
3. Push the bayonet of the power
scrubbing brush back into
the bayonet socket and secure
connection by tightening the
H
upper nut
.
Advantage : The two working
positions allow horizontal and
vertical areas to be easily cleaned
(fig. L).
The Power Scrubbing
6.6 Terminating work (fig. M)
Brush must not be used
Attention! When using cleaning
rings, flush the unit thoroughly
with water after use to rinse
out the residual cleaning agent
as sediment will otherwise cause
interference with subsequent
operations:
1. Set the adjusting knob
of the dispens-
ing unit to
this position:
The dispensing function
is shut off and clear water
is delivered (fig. M 1).
G
2. Flush the unit for approx.
1 minute with clear water.
3. Turn the tool off (ON / OFF
switch to position 0, figure M 2).
4. Turn off the water supply
(fig. M 3).
C
of the high-
7. Trouble-shooting
Fault
Motor does not run
when switched on.
The Power Scrubbing Brush
does not build up sufficient
pressure.
H
of
Fluctuations in the working
pressure.
Pump leaks.
No cleaning agent dispensed.
5. Actuate the high-pressure gun
to lock the gun so as to pre-
C
using the operating lever
vent any accidental opening
until emptied of all water and
(fig. M 4).
is at ambient pressure, and
6. Unplug the mains connector
$
then press the safety button
plug from the outlet socket.
Possible causes
Remedy
Check that the voltage given on
the nameplate is consistent with
the mains voltage.
Connecting cable damaged.
Check the connecting cable
for damage.
Connector plug not plugged
Check the connector plugs and
in correctly.
cable, have the switch checked by
Intermittence in the power
an authorised GARDENA Service
supply.
agent.
Mixing unit adjust-
Mixing unit ad-
ment knob set
justment knob
to position:
in position:
Air in the system.
Run the pump without the
high-pressure hose until water
exits the high-pressure outlet
without any bubbles.
Then connect the high-pressure
hose again.
Sieve in the water connection
Unscrew the tap connector,
blocked.
take out the sieve and clean.
Insufficient water admitted.
Check the amount of water
being admitted.
Leaks / blockage in the inlet line.
Check all inlet lines for blockage
and leaks.
High-pressure nozzle blocked.
Clean the high-pressure nozzle
by removing any dirt in the
nozzle with a needles and flush
out with running water.
Pump draws in air.
Check the suction lines for leaks.
It is usual that the pump leaks
Please consult GARDENA
to a small degree.
Service if the leak is large.
Dispensing unit incorrectly set.
Open the dispensing unit by
setting the switch to the "MIX"
position.
No cleaning rings in the
Place cleaning rings in the
dispensing unit.
dispensing unit (see 6.3 for this).
G
17