Electrical Installation
Terminals description
Connector / Name
ALARM1
DC = voltage
Terminal
control *)
contact
control
ALARM2
contact
terminal
control
CANCEL
DC = voltage
terminal
control *)
contact
control
Indicator terminals *)
Connectors for external LED
supplied from Lift1
Connector for external
microphone
Connector for external
speaker
Connector for induction loop
Connectors
VAS ALARM1
VAS ALARM2
PROGRAMMIG CONNECTOR
Jumper Recovery mode –
accessible after cover
replacement
Switch contact *)
Lift blocking contact *)
Power for amplifier *)
*) These terminals are safely electrically isolated from the telephone line.
The ALARM1 terminal block helps activate alarm calls.
The ALARM2 terminal block can be used for alarm to different set of numbers, especially with
Voice alarm station, or for end of alarm setting. Only isolated switch with normally open contact
can be used.
The CANCEL terminal block helps deactivate an active alarm when the door opens. Therefore, set
parameter 914 to a value higher than the maximum lift travelling time.
For the Alarm 1 and Cancel input can be used switch button both with normally opened or
normally closed contacts, isolated. The isolated voltage inputs can be activated by any voltage
from 12 to 24 V. The logic of inputs is to be set by parameters (920 for Alarm 1, 916 for Cancel).
12–24 V DC, any polarity,
activation by signal or no signal
state possible
normally open or normally closed
contact
Normally open contact only
12–24 V DC, any polarity,
activation by signal or no signal
state possible
normally open or normally closed
contact
Indicators (illuminated pictograms) up to 24 V / 2x 200 mA,
externally supplied, wiring diagram must be maintained
Exteral LED connected to phone
line – se the Safety caution
External microphone, to be placed
according installer needs
External speaker, to be placed
according installer needs
Induction loop for person wit
hearing aid
For Voice Alarm Station
connection, only one of them can
be used concurrently
USB programming tool for 2N
Service Tool via PC
Set the jumper to ON to activate the recovery mode for FW
upgrade whenever a problem occurs with the Lift1 – 2N
Service Tool connection.
The switches are used for variable purposes and are
remotely DTMF-controlled. The switches are not designed for
230 V! Switch or lift blocking contact can be used.
The contact opens whenever a phone line failure occurs. It
allows signaling or lift blocking.
Amplifier module needs external power source
Description
Alarm call activation
Alarm 2 call or end of
rescue mode
Alarm call deactivation
upon door opening
Supplied with cable
version of Lift1
Supplied with cable
version of Lift1
Supplied with cable
version of Lift1
Accessory equipment
Activates Alarm1 or
Alarm2 according used
connector
®
configuration,
firmware, voice menu
EN
®