A-Neutronics NP-26024 Manual de instrucciones - Página 5
Navegue en línea o descargue pdf Manual de instrucciones para Regletas de enchufes A-Neutronics NP-26024. A-Neutronics NP-26024 8 páginas. 24-outlet lcd display vertical power strip 20amp
LCD DISPLAY METER FUNCTION
METER FUNCTION
RE-SET KWH AND CLOCK
Power cycle the unit by turning it OFF and then ON again. This will reset the KWH and clock.
SET OVER CURRENT WARNING LEVEL
This power strip is designed to operate at 20Amps. Changing this Over Current Warning Level value does not allow more then the
specified amperage as specified on the product label.
1. Press "SET" button for (3) seconds.
2. Press "FNC" button so the display is either 15A or 30A.
3. Press "SET" button to select the new setting.
4. Press "FNC" button to return to normal operation.
(8) FUNCTIONS PROVIDED
Plug in the power strip and it starts to display current power supply status
•
Voltage
•
Amp
•
Watt
•
VA
•
Hz
•
PF
•
Kwh
•
Runtime Clock
No start button required. FUNCTION and SET buttons are located on the right side of the
LCD Display.
OPERATION
1. Plug in the strip, the display will show the voltage reading.
2. Press "FNC" button, to show amperage reading.
3. Press "FNC" button again, to show watt reading.
4. Press "FNC" button again, to show VA (apparent power) reading.
5. Press "FNC" button again, to show Hz (frequency) reading.
6. Press "FNC" button again, to show PF (power factor) reading.
7. Press "FNC" button again, to show KWH (kilo watt per hour) reading.
8. Press "FNC" button again, to show runtime (clock).
OVER VOLTAGE AND OVER CURRENT WARNING
1. LCD display will show "OUP" when the input voltage is over 145V.
2. LCD display will "blink" when the input current is over 20A.
FUNCTION
Volts
Amps
Watts
VA
Frequency
Power Factor
KWh
KWh hour
3
RANGE
ACCURACY
95.0~125 Vrms
0.2%
0.00~20.0 Amps
0.3%
2500 Watt
0.5%
2500 VA
0.5%
47.0~63.0Hz
+/- 0.1Hz
0.00~1.00
0.01%
0.00~9999
.5%
0.00~9999
30ppm