A-Neuvideo EP-132 Manual de instrucciones - Página 9
Navegue en línea o descargue pdf Manual de instrucciones para Media Converter A-Neuvideo EP-132. A-Neuvideo EP-132 20 páginas. Serial to ethernet converter
A
NEUVIDEO
Initial IP Configuration
When setting up your converter for first time, the first thing you should do configure the IP address. This chapter introduces of method to
configure the device server IP address. For more details about network settings, see "Web Console Configuration" in next sub section.
For quick setup of converter, we suggest you reference the
Device Management Utility of ETM
Due to nature of broadcast UDP packets, ETM has following characteristics:
• Broadcast packets aren't limited by subnet. If even IP address of converters and computer running ETM do not belong to same
subnet, it still works fine.
• Broadcast packets can not pass routers. ETM can only be used to monitor devices with computer running ETM in same segment
of local area network.
Menu "View"
(Figure 3.1)
(Figure 3.2)
Converter Configuration
"Quick Installation guide."
On PC we provide Device Management Utility named
ETM.exe which an executable program in Windows 32 bit
environments. ETM Setup Tool used to detect and setup
the installed converters. It uses UDP broadcast packets
to query and configure converters on the network.
When you activate the tool, it will detect the existence
of installed converters and depict the converters status
such as IP address, Subnet Mask, MAC Address and
Device ID (see Figure 3.1).
If your computer OS is Windows xP version which means
"WINDOWS Firewall" function in OS activated. However
ETM.exe wouldn't detect the converter IP address,
therefore, you have to temperately disable "WINDOWS
Firewall" function. After finishing the parameters settings,
you can restart "WINDOWS Firewall" function.
• View - > Refresh F5: Refresh the status. ETM will
send another query to get updated information. (See the
Figure 3.2.)
Note: Always run the "View-> Refresh" after any data
change.
• View - > Exit Alt+F4: Exit from the program (see Figure 3.2).
7