Fencee power energy PE60 Manual del usuario - Página 10

Navegue en línea o descargue pdf Manual del usuario para Fuente de alimentación Fencee power energy PE60. Fencee power energy PE60 16 páginas.

EARTHING
Correct earthing is very important because total function of the fence system is
dependent on it!
Beat earthing rod with corrosion protection into ground completely at place with maximum
and permanent humidity. On dry pieces of land or in case of soils with lower electric
conductivity, use one or several supplementary earthing rods (with length of minimum
of 1 m) and place them at distance of approximately 3 meters from each other.
Exceptions are fence system powered by battery energizer or working with low output.
Here minimum length of earthing rod of 50 cm is recommended.
Distance of at least 10 meters must be between earthing rod of the fence system and another
earthing system, for example earthing of a house, protective earthing of electric supply system
or earthing of violation alarm.
Do not connect the energizer to already existing earthing or to the the earthing
of another energizer. Each energizer must have its own earthing.
Connection of the output terminals
Connect the black earthing clip with the earthing cable to the earthing rod.
Connect the red clip with the connecting cable to the fence.

8. CONTROL

10
The energizer remembers its last status and reactivates in it.
Therefore, the use of a switching or time socket is possible.
ON / OFF and power output
switching push button
For basic control is used large control
push ON/OFF button.
This button can be used to turn
the energizer on and off.