9. EXPLANATION OF LED INDICATING LIGHTS

COLOR:
• Green - common operation
• Red It lights up when voltage on fence drops below 3 kV.

10. SAFETY GUIDELINES

Install and operate the electric fence systems in such a way that they do not pose the risk of
electric shock to humans, animals or disturb the environment.
Avoid using the electric fence systems that could trap animals or people.
One electric fence system must not be powered by two or more energizers or by independent
power supply devices designated for electric fence systems of the same equipment.
When operating two or more different electric fence systems and if they are powered by
different energizers, the minimum distance between the electric fences must be 2.5 m.
Use electrically non-conductive material if this distance is required to be smaller.
Do not use barbed or razor wire or any other types of sharp-edged wire to install the
electric fence system.
Non-conductive additional fencing in which barbed or razor wire is used must be at least
150 mm from the electric fence system wire and must be earthed at regular intervals.
All electric fence system sections installed along the public roads must be marked with
warning signs attached to poles or fences at regular intervals and visible from the road.
Warning sign
• It is of yellow colour with minimum dimensions of 100 × 200 mm
• It is either standard warning sign or contains the following
Inscription on both sides: WARNING! ELECTRIC FENCE
• Letters must be at least 25 mm high and indelible
• One warning sign is included in the package contents
Power supply and connecting cables
• Cables that are rated for voltages higher than 1 kV and are located in buildings must be
effectively insulated from the building's earthing features. This may be achieved by using
insulated high-voltage cables or by leaving appropriate distance between the cable and
the building frame. Do not use standard electrical cables
LED control of operation (top):
• Permanent burning
energizer on, powered from 230 V mains
LED control of function (bottom):
• Blinking in the pulse interval
11