buttons, provided that the appliance is in programming mode.
Note: When you turn on the appliance, it will start operating in the (heating
or programming) mode which it has last operated.
Note: You can switch between the modes of operation (heating or
programming) by shortly pressing the "Timer" button when the
appliance is switched on.
"Return to factory settings" function
When the convector is in "Off" mode, press the
simultaneously for six seconds; then the display will show „_ _ __" and rotating
symbols. When it is "reset", the display will show the measured value of the
room temperature.
After using the reset function, you need to re-enter the settings of the
following functions:
•
time setting
•
enter a value of the temperature correction (if needed)
•
disable the "Anti-frost" function (if needed)
•
disable the "Adaptive start" (if needed)
•
weekly programme - 24/7
If the electric convector is disconnected from the mains, this will not affect
the set temperature and the mode of operation which has been active prior
to its disconnection. If for example the convector has been in "Heating" mode,
after it has been disconnected and reconnected to the mains, it will continue
operating in the same mode with the same set temperature.
The principle of operation of the electric convector with energy-
independent memory is to store the settings for 90 minutes
guaranteed, and up to 150 minutes not guaranteed.
When the room temperature is lower than the temperature set by the
electronic thermoregulator, the convector will start operating and will
continue operating until the room temperature reaches the set value. When
the room temperature is higher than the temperature set by the electronic
thermoregulator, the convector will automatically go into "Standby" mode.
Information presented on panel heater display
Indications when you are not in settings mode:
a. In Off mode – consecutively showing:
•
time (hour and minutes)
•
measured room temperature
b. In Heating mode – it shows the measured room temperature
c. In Programming mode – consecutively showing:
•
Day of the week, low line and the measured temperature. 6_22
•
Day of the week, low line and the temperature set in the programme
blinking (set for the current hour), which may be also the OFF symbol. 6_23
d. Upon connecting the convector to power supply the display shows:
•
Hyphens "----", if the appliance has been in Off mode before disconnecting
it from the power supply.
•
Hyphens "----", which in 2 seconds will be replaced by the value of the
current temperature, if the appliance has been in On mode before
disconnecting it from the power supply.
e. Two numerals (01÷96) and a blinking yellow LED indicate the remaining time
in hours until the delayed start, if the appliance has been in "Delayed start"
mode before disconnecting it from the power supply.
f.
With the purpose of further energy saving, the electronic thermoregulator
reduces the brightness of illumination of all LEDs. Upon pressing any of the
buttons the brightness increases for 8 seconds and it is then reduced again.
g. If the display shows "t1" or "t2", this means that the self-diagnostic system has
found a problem with the temperature sensor. "t1" indicates a disconnected
cable at the sensor, while "t2" indicates short circuit at the sensor. In this case
the electric convector will be automatically switched off and it can be switched
on again only after the problem has been fixed. The problem has to be handled
by a qualified specialist.
h. Upon switching on the power supply the display will show hyphens "----" for 2
seconds instead of temperature of time.
i.
When the digital display shows the temperature the "Temperature" LED is lit,
and when it shows the time, the "Timer" LED is lit.
PROTECTION
•
The appliance is equipped with a safety thermo turn-off device, which
English
•
CLEANING
•
and
buttons
•
•
•
STORAGE
•
•
•
•
•
MAINTENANCE OPERATIONS OF THE APPLIANCE
•
•
DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM /
APPLIANCE MODELS
Model
DZ 024 050 EIS W - 500W
DZ 024 100 EIS W - 1000W
DZ 024 150 EIS W - 1500W
DZ 024 200 EIS W - 2000W
DZ 024 250 EIS W - 2500W
* Minimum guaranteed heated volume (area) for heating at an average capacity of heat transmission
factor λ=0.5 W/(m
average value of λ=0.35 W/ (m
automatically turns the heater off in cases of extreme temperature of the
panel heater /i.e. overheating of the appliance/.
The safety thermo turn-off device will automatically restore the heater
operation when the temperature of the appliance falls below the
permissible ultimate values.
It is compulsory first to turn off the appliance through its power
switch and to disconnect it from the power socket. Before starting the
cleaning session you should wait until the panel heater cools down in a
disconnected state.
Clean the heater body with damp cloth, vacuum cleaner or a brush.
Never immerse the appliance into water – there is danger for your life from
electric shock!
Never use gasoline, thinner or hard abrasive products to clean the
appliance, because they will damage the appliance coating.
Before putting the panel heater away let it cool down after you have
disconnected it from the power socket
Use the appliance original packing to store it, if the panel heater will not
be in use for a long period of time. By storing the product in its original
packing you protect it from excessive dirt and dust accumulation.
Never put a hot panel heater in its packing!
It is necessary the product to be stored at a dry and dark place, protected
from direct sun light.
It is explicitly forbidden to store the panel heater in damp and wet premises.
In case of appliance malfunction, please contact the authorized service
center closest to your location. /service centers are indicated in appliance
warranty documents/.
Important: In case of a claim and/or violation of your consumer rights,
please contact the supplier of this appliance at the indicated locations or
via the Internet page of the company: www.tesy.com
Heated volume
10* - 15 m
3
20* - 30 m
3
30* - 45 m
3
40* - 60 m
3
50* - 70 m
3
K) for a heated room. Higher values of heated volume (area) can be achieved at an
2
K). Standard height of heated rooms – 2.5 meters.
2
Heated area
4* - 6 m
2
8* - 12 m
2
12* - 18 m
2
16* - 24 m
2
20* - 28 m
2
Operation and Storage Manual of Panel Heater
EN