Aqua Lung Legend LX Second Stage Manual técnico de mantenimiento - Página 16

Navegue en línea o descargue pdf Manual técnico de mantenimiento para Controlador Aqua Lung Legend LX Second Stage. Aqua Lung Legend LX Second Stage 18 páginas.

Aqua Lung Legend LX Second Stage Manual técnico de mantenimiento
16
PART NUMBER
AP2031
APF124563
TEST
Leak Test
Intermediate Pressure
Intermediate Pressure
Creep
Opening Effort
Flow effort
Purge flow
Table 4 - Torque Specifications
DESCRIPTION / KEY NUMBER
Retaining nut / 15
Table 5 - Test Bench Specifications
CONDITION
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Intermediate pressure 135±5 psi
Intermediate pressure 135±5 psi
Intermediate pressure 135±5 psi
Hose / 40
No leaks allowed
135±5 psi
5 psi max between 5 to 15 seconds after
cycling (purging) regulator
+0.8 to +1.4 in. H
+1.1 to +1.7 in. H
+6 inches H
5.0 SCFM flow rate (minimum)
Legend First Stage Service Manual
TORQUE
45±2 inch-lbs
40±2 inch-lbs
ACCEPTABLE RANGE
0 (primary)
2
0 (Supreme)
2
0 (maximum) at 15 SCFM
2