Aqua Lung Legend LX Second Stage 기술 유지보수 매뉴얼 - 페이지 16

{카테고리_이름} Aqua Lung Legend LX Second Stage에 대한 기술 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Lung Legend LX Second Stage 18 페이지.

Aqua Lung Legend LX Second Stage 기술 유지보수 매뉴얼
16
PART NUMBER
AP2031
APF124563
TEST
Leak Test
Intermediate Pressure
Intermediate Pressure
Creep
Opening Effort
Flow effort
Purge flow
Table 4 - Torque Specifications
DESCRIPTION / KEY NUMBER
Retaining nut / 15
Table 5 - Test Bench Specifications
CONDITION
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Intermediate pressure 135±5 psi
Intermediate pressure 135±5 psi
Intermediate pressure 135±5 psi
Hose / 40
No leaks allowed
135±5 psi
5 psi max between 5 to 15 seconds after
cycling (purging) regulator
+0.8 to +1.4 in. H
+1.1 to +1.7 in. H
+6 inches H
5.0 SCFM flow rate (minimum)
Legend First Stage Service Manual
TORQUE
45±2 inch-lbs
40±2 inch-lbs
ACCEPTABLE RANGE
0 (primary)
2
0 (Supreme)
2
0 (maximum) at 15 SCFM
2