Allied Telesis AT-PB200 Series Manual de instalación rápida

Navegue en línea o descargue pdf Manual de instalación rápida para Interruptor Allied Telesis AT-PB200 Series. Allied Telesis AT-PB200 Series 2 páginas. Fast ethernet switches

Allied Telesis AT-PB200 Series Manual de instalación rápida
Technical Specifications
Maximum Operating Temperature:
Maximum Storage Temperature:
Operating Altitude:
Humidity:
EMC:
Safety:
Electrical Safety and Emission Statement
Standards: This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
RFI Emission
EN55022 Class A
Warning: In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Immunity
EN55024
Electrical Safety
EN60950, UL1950 (UL/cUL)
Laser
EN60825
Copyright  2002 Allied Telesyn, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission
from Allied Telesyn, Inc.
Allied Telesyn, Inc.
960 Stewart Drive, Suite B
Sunnyvale, CA 94085 USA
Tel 1 (408) 730-0950 • Fax 1 (408) 736-0100
Visit our web site at: www.alliedtelesyn.com
4
0° C to 40° C (32° F to 104° F)
-20° C to 80° C (-4° F to 176° F)
Up to 3,048 meters (10,000 feet)
5% to 80% (non-condensing)
FCC Class A, EN55022 Class A, EN55024
EN60825, EN60950, UL1950 (UL/cUL)
AT-PB200 Series
Fast Ethernet Switches
Quick Install Guide
For use in the PowerBlade Chassis
Overview
The AT-PB200 Series Fast Ethernet Switches are hot swappable modules for the
PowerBlade Chassis. The AT-PB200 Series Switches are designed to interconnect LAN
devices and subnetworks over large distances into an integrated network. These dual-
port switches can also be used to improve the performance of your network by dividing it
into smaller, more manageable segments. Each switch features a 10/100Base-TX
twisted pair port and an 100Base-FX fiber optic port. The twisted pair port has an RJ-45
connector and a maximum operating distance of 100 meters (328 feet). The fiber optic
port has a FJ, SC, ST, LC, MT-RJ, or VF-45 connector and a maximum operating
distance of 2 kilometers (1.2 miles) to 100 kilometers (62 miles), depending on the
model.
Related Documents
This quick install guide is an abbreviated version of the installation procedures. For
complete details on the features and functions of the Ethernet switches and additional
installation instructions, refer to the PowerBlade Chassis Installation Guide. This guide
is available from the Allied Telesyn web site at www.alliedtelesyn.com.
Cable Specifications
The following table lists the maximum operating distances for the AT-PB200 Series
Switches.
10/100Base-TX
Model
Connector
Maximum Distance
AT-PB201
RJ-45
100 m (328 ft)
AT-PB202
RJ-45
100 m (328 ft)
AT-PB202/1
RJ-45
100 m (328 ft)
AT-PB202/2
RJ-45
100 m (328 ft)
AT-PB202/3
RJ-45
100 m (328 ft)
AT-PB202/4
RJ-45
100 m (328 ft)
AT-PB204
RJ-45
100 m (328 ft)
PN 613-50148-00 Rev C
100Base-FX
1
2
Connector
Maximum Distance
2 km (1.2 mi)
ST
SC
2 km (1.2 mi)
SC
15 km (9.3 mi)
SC
40 km (24.8 mi)
SC
70 km (43.4 mi)
SC
100 km (62 mi)
MT-RJ
2 km (1.2 mi)
020626