6) For KCU105 board by AB17, open Serial console to connect with Enhanced COM port
(Buad rate=115,200 Data=8 bit Non-Parity Stop=1). The console shows System
Controller menu, as shown in Figure 2-8. To set VADJ of FMC to 1.8V, the following step is
recommended.
i. Input '4' to select Adjust FMC Settings.
ii. Input '4' to set FMC VADJ to 1.8V.
iii. Input '0' to return to Main Menu.
iv. Input '2' to get PMBUS Voltages.
v. Input '7' to get VADJ1V8 Voltage. The output voltage of this menu must be equal to
1.8V to confirm that VADJ has been set completely.
For more details of System Controller, please check "UG917 KCU105 Board User Guide"
in section "Appendix C: System Controller".
https://www.xilinx.com/support/documentation/boards_and_kits/kcu105/ug917-kcu105-e
val-bd.pdf
3-Aug-22
Figure 2-8 Setting VADJ on FMC for KCU105