Common setup

Enter the following commands to restore the factory configuration for bridged mode:
AT-WR4600# copy nvram:/factory-config-routed startup-config
AT-WR4600# reload
Configure the common SSID for open authentication:
AT-WR4600(config)# dot11 ssid ATIopen
AT-WR4600(config-ssid)# authentication open
AT-WR4600(config-ssid)# guest-mode
AT-WR4600(config-ssid)# exit
Note: In this example network, each node belongs to a different wired LAN (subnet). You may build
the same wireless service using bridged mode, so that all nodes are all in the same subnet.

[P1] station role: root access-point

Configure the station role; assign the IP address and the SSID to the radio interface:
AT-WR4600(config)# interface dot11radio 0
AT-WR4600(config-if)# station-role root access-point
AT-WR4600(config-if)# ip address 10.0.0.100/24
AT-WR4600(config-if)# ssid ATIopen
AT-WR4600(config-if)# no shutdown
AT-WR4600(config-if)# end

[STA1] station role: workgroup-bridge

Configure the station role; assign the IP address and the SSID to the radio interface:
AT-WR4600(config)# interface dot11radio 0
AT-WR4600(config-if)# station-role workgroup bridge
AT-WR4600(config-if)# ip address 10.0.0.1/24
AT-WR4600(config-if)# ssid ATIopen
AT-WR4600(config-if)# no shutdown
AT-WR4600(config-if)# end

[STA2] station role: workgroup-bridge

Configure the station role; assign the IP address and the SSID to the radio interface:
AT-WR4600(config)# interface dot11radio 0
AT-WR4600(config-if)# station-role workgroup bridge
AT-WR4600(config-if)# ip address 10.0.0.2/24
AT-WR4600(config-if)# ssid ATIopen
AT-WR4600(config-if)# no shutdown
AT-WR4600(config-if)# end
10