Dell PowerEdge R320 Manual de introducción - Página 10
Navegue en línea o descargue pdf Manual de introducción para Servidor Dell PowerEdge R320. Dell PowerEdge R320 11 páginas. Poweredge series
También para Dell PowerEdge R320: Manual (11 páginas), Especificación (2 páginas), Manual de cartera (27 páginas), Manual de introducción (9 páginas), Manual de introducción (9 páginas)
Environmental
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
10
One shock pulse in the positive z axis (one pulse on
each side of the system) of 31 G for 2.6 ms in the
operational orientation
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 32 G faired square wave
pulse with velocity change at 270 inches/second
(685 centimeters/second)
–15.2 m to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1 ºF/550 ft.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985