Environmental
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
10
One shock pulse in the positive z axis (one pulse on
each side of the system) of 31 G for 2.6 ms in the
operational orientation
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 32 G faired square wave
pulse with velocity change at 270 inches/second
(685 centimeters/second)
–15.2 m to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1 ºF/550 ft.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985