Dell Networking Z9500 Manual de instalación - Página 32
Navegue en línea o descargue pdf Manual de instalación para Interruptor Dell Networking Z9500. Dell Networking Z9500 47 páginas. Z9500 switch
También para Dell Networking Z9500: Manual de introducción (34 páginas)
Securing Power Cables
1.
Bend the system power cables, as shown in the following illustration, and attach to the cable clasp.
NOTE: Install all four PSUs before securing the power cables.
Figure 10. Securing Power Cables
1.
Velcro strap
2.
Plug the other end of the power cables into a grounded electrical outlet or a separate power source
such as an uninterruptible power supply (UPS) or a power distribution unit (PDU).
CAUTION: The switch has a high line-voltage requirement of minimum 200V.
NOTE: For better performance, ensure that the system is connected to a stand-alone power source
with stable power supply.
Installing the Cable Management System (OPTIONAL)
You must order the cable management mount assembly separately. Mount the assembly on the top front
of the chassis to organize network cables and to minimize obstruction from these cables while you insert,
remove, and view the chassis components. Using the cable management system, you can attach the
maximum number of cables in Z9500 I/O ports.
NOTE: The installation of the cable management system requires that you install these parts in the
order presented in this document. It is recommended that you install the cable management system
after the chassis is installed into the rack or cabinet.
WARNING: When you cable the ports, be sure not to interfere with the airflow from the small vent
holes above and below the ports.
32
2.
Power Cable
Z9500 Installation