Dell PowerConnect 8024 Notas de publicación - Página 10
Navegue en línea o descargue pdf Notas de publicación para Interruptor Dell PowerConnect 8024. Dell PowerConnect 8024 20 páginas. Upgrading from version 2.x.x.x or 3.x.x.x or 4.x.x.x or 5.x.x.x to 5.1.9.3 firmware
También para Dell PowerConnect 8024: Notas de publicación (27 páginas), Manual de configuración (21 páginas), Actualización del firmware (24 páginas)
PowerConnect 8024/8024F Release Notes
Description
Switch throws errors of level
info/debug when clearing PFC
interface counters or checking PFC
interface counters.
Switch uploads startup-config when
tried uploading running-config.
PFC counters on LAG interface are
not incrementing.
Summer Time enabled does not
reflect correctly in the output of 'show
running-config' and 'show clock detail'.
Recurring Summer Time is getting
configured for max offset value even
though offset is not configured.
Location information is not found in
CLI / Web when Recurring Summer
Time is configured.
Summer Time does not work when
date falls under configured window.
Web does not show starting / ending
month & year for non-recurring
summer time configuration.
IGMP Queriers are sent out from the
switch after the pre-configured 60
secs interval
Summer Time offset range is not
correct.
Failed to delete configured radius
server key
Upgrade PHY firmware to version
1.4.1.0
Switch is accepting any letter other
than "y" to generate SSH key.
No button is selected by default in the
copy file web page
Page 8
User Impact
Error messages are displayed on the
console and the counters not
incremented properly due to
misintepreted failure conditions.
Running-config cannot be uploaded
from web.
Error messages are displayed on the
console and the counters not
incremented properly due to
misinterpreted failure conditions.
When summer time is configured, the
time reported is incorrect.
When summer time is configured, the
time reported is incorrect.
show commands do not reflect the
correct status, when summer-time for
EU or USA is configured.
When summer time is configured, the
time reported is incorrect.
The Start Month and Year, End Month
and Year fields were missing in the
Clock Detail Web page.
Partner would receive IGMP querier
packets later than the expected time,
even though the delay is neglected.
User is allowed to configure out of
range values from the web page.
Radius server key cannot be deleted
once it's configured
10G copper ports may take 2-5
minutes to link-up.
Switch generates SSH key on
entering anything other than 'n' letter,
even though help is saying that it
allows only 'y' or 'n'.
No button is selected by default in the
copy file web page
Resolution
Now counters are properly handled
based on the applicable registers.
Corrected algorithm to determine
proper file type to upload.
Now counters are properly handled
based on the applicable registers.
Updated the algorithm to correctly
calculate the summer-time period.
Updated the algorithm to correctly
calculate the summer-time period.
Detect when the configuration
matches those modes to allow user
to identify what mode was selected.
Updated the algorithm to correctly
calculate the summer-time period.
Added missing fields to the web
page
Updated cpu utilization mechanism
along with using accurate values for
system clock.
Corrected help string along with field
validations.
Added no command support for
deleting key from Radius
configuration mode.
Switches automatically upgrade the
PHY firmware that corrects link up
time.
Modified validation to not allow
anything other than 'y'/'n'
Modified web page to have a default
selection.
System Firmware Version 3.1.4.16