Dell PowerConnect 8024 Notas de publicación - Página 9

Navegue en línea o descargue pdf Notas de publicación para Interruptor Dell PowerConnect 8024. Dell PowerConnect 8024 20 páginas. Upgrading from version 2.x.x.x or 3.x.x.x or 4.x.x.x or 5.x.x.x to 5.1.9.3 firmware
También para Dell PowerConnect 8024: Notas de publicación (27 páginas), Manual de configuración (21 páginas), Actualización del firmware (24 páginas)

Dell PowerConnect 8024 Notas de publicación
Description
The show ip igmp groups vlan detail
does not show any registered MC
groups.

Release 3.1.4.8

Description
Occasionally, the switch will stop
responding to SNMP
Release 3.1.4.5
Description
IGMP Querier does not work if IP
Multicast not enabled.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
Radius Servers always show active
status.
PFC frames received per priority
queue are always shown as zero.
productIdentificationPerUnitTable OID
was re-numbered when banner OIDs
were inserted.
BPDU protection fails when port is in
dot1x un-authorized state.
Code Download is getting failed with
HTTPs as management session and
downloading protocol as HTTP.
Service Port MAC address is not valid
System Firmware Version 3.1.4.16
PowerConnect 8024/8024F Release Notes
User Impact
Only detail fails to show registered
MC groups. Other commands show
the groups correctly.
User Impact
The switch will become unresponsive
with the message "Timeout: No
Response from AA.BB.CC.DD."
User Impact
User must enable IP multicast in order
for IGMP Querier to function properly.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
The RADIUS Server Status web page
was always displaying the server's
status as active.
Per priority PFC frames received
count is always zero.
Management applications that use the
OID in the 3.1.1.9 release will not
work properly.
When the port is in Dot1x
Unauthorized mode STP bpdus will
not be allowed to the Dot1s
application and increase CPU
utilization.
Code Download is getting failed with
HTTPs as management session and
downloading protocol as HTTP.
The OOB port is not using the correct
MAC address, even though the output
of "show ip interface out-of-band"
shows the correct MAC address.
Resolution
Corrected the show ip igmp groups
detail command.
Resolution
Semaphores were added to protect
data from becoming corrupted.
Resolution
Automatically enable IP Multicast
when IGMP is enabled.
The driver modified to handle MAC
addresses correctly to prevent the
log messages.
Retrieved the server status the
same as the CLI for each row in the
web page display.
PFC frames statistics are not
properly reported.
Reverted the OID to the proper
value used on the other
PowerConnect switches.
Allow STP BPDUs without
considering the dot1x authorized
state of the port.
Pass correct file path when HTTP is
selected as the download method.
Initialized driver to properly process
the MAC Address.
Page 7